15
CTC EcoPart i425-i435 Pro
1
3
2
4
5
8
6
7
9
10
11
12
13
15
14
16
17
1.
Brine (heat source)
2.
Water
3.
Evaporator
4.
Condenser
5.
Compressor
6.
Expansion valve (electronic)
7.
Drying filter
8.
Refrigerant heat exchanger
9.
Low pressure sensor
10. High pressure sensor
11. High pressure switch
12. Temperature suction gas
13. Temperature discharge
14. Temperature brine
15. Temperature water out
16. Temperature water in
17. Control expansion valve
2.5 Refrigerant system
The schematic diagram shows the refrigerant system for each integrated
heat pump module.
2.6 Operating range
CTC EcoPart’s pressure-controlled operations monitoring means that the
brine temperature (B) and heat medium temperature (H) can automatically be
increased where this is possible.
Operating condition:
B temp/H temp °C
1
-5 / 25
2
20 / 25
3
-5 / 61
4
20 / 64
Operating limits as per the table above are defi ned in accordance with EN 14511-4.
Summary of Contents for EcoPart 425
Page 38: ...38 CTC EcoPart i425 i435 Pro 5 5 Wiring diagram for CTC i425 i435 Pro 400V 3N...
Page 39: ...39 CTC EcoPart i425 i435 Pro...
Page 40: ...40 CTC EcoPart i425 i435 Pro 5 6 Electrical diagram cooling module 400V 3N CTC EcoPart 406 417...
Page 41: ...41 CTC EcoPart i425 i435 Pro...
Page 42: ...42 CTC EcoPart i425 i435 Pro 5 7 Electrical diagram CTC EcoPart i425 i430 Pro 230V 1N...
Page 43: ...43 CTC EcoPart i425 i435 Pro...
Page 44: ...44 CTC EcoPart i425 i435 Pro 5 8 Power supply and communication 230V 1N CTC EcoPart 425 430...
Page 45: ...45 CTC EcoPart i425 i435 Pro 5 9 Power supply and communication 400V 3N CTC EcoPart 425 435...
Page 46: ...46 CTC EcoPart i425 i435 Pro 5 10 Electrical diagram cooling module 230V 1N...
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......