background image

4308 Quadradiant

Page 31

N

N

O

O

T

T

E

E

S

S

Summary of Contents for Chore-Time QuadRadiant

Page 1: ...y of its subsidiaries or divisions hereafter collectively referred to as CTB Subsequent changes to any manual made by any third party have not been reviewed nor authenticated by CTB Such changes may i...

Page 2: ...Page 2 1408 Quadradiant Assembled in the U S A...

Page 3: ...table means Example soap and water solution or a pressure check Do not use open flame to test for gas leaks Do not operate the heater until this test has been performed Use only the type of gas being...

Page 4: ...ctrica de tres polos Heaters must be electrically grounded in accordance with the National Electrical Code ANSI NFPA 70 or the current Canadian Electrical Code CSA C22 1 Polarity of Line voltage and n...

Page 5: ...lds are missing A See pages 18 21 in the installation and operation manual 7 Sensor Location Q Have you positioned your temperature sensors correctly A See page 14 in the installation and operation ma...

Page 6: ...que ninguno falta A Vea las p ginas 18 21 7 Ubicaci n de sensor Q Ha colocado usted sus sensores de temperatura correctamente A Vea la p gina 14 8 Colgamiento Q Est n los puntos de suspensi n para sus...

Page 7: ...TO BE INSTALLED BY CERTIFIED INSTALLERS ONLY ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THESE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER During normal operation the surfaces of the unit become ve...

Page 8: ...E CONTACT PHYSIQUE ESTE APARATO TIENE CALOR DURANTE la OPERACION NORMAL EVITE el CONTACTO FISICO DANGER DO NOT ATTEMPT TO CLEAN THE HEATER WHILE IT IS OPERATING OR WHILE IT IS STILL HOT Ne PAS TENTER...

Page 9: ...acturer requires the installation of the drip leg in order to help keep the gas orifice free from debris commonly found in gas lines Use approved certified and sealant on all connections Horizontal In...

Page 10: ...The pressure should not drop below 4 5 P S I If the pressure does fall below 4 5 P S I then the gas distribution system is inadequately designed The problem may be a regulator pipe sizing etc GAS SUPP...

Page 11: ...TER SAFETY CLEARANCE The heater must be located so there is a minimum clearance to combustible material of 24 minimum of 12 if heat deflectors are used above the heater and 48 from the side The heater...

Page 12: ...Page 12 1408 Quadradiant...

Page 13: ...heater Failure to follow these instructions could result in serious personal injury or significant property damage WARNING Failure to follow the instructions in this manual could result in serious per...

Page 14: ...nsor should be placed over the feeder or drinker line Suspend sensor 12 to 16 off the floor Sensor should be no more than10 12 feet to the side from the center or 10 feet lengthwise from the center of...

Page 15: ...winching make certain that ALL hoses and power supply cords are NOT resting on the heater nor are within 12 of the heater Hanging Points Pulleys should be mounted in the ceiling and posi tioned 6 wid...

Page 16: ...inched up or down THIS HOSE INSTALLATION IS CORRECT The gas supply installation shown in the illustration above allows the gas supply hose to hang AWAY from the surfaces of the heater even during winc...

Page 17: ...E INSTALLATION IS WRONG The gas supply hose is touching the heater More of the hose will rest on the heater during winching The gas supply hose is touching the heater More of the hose will rest on the...

Page 18: ...Page 18 1408 Quadradiant Each unit requires two Left Deflectors and two Right Deflectors...

Page 19: ...4308 Quadradiant Page 19 NOTE Narrow holed side of the deflectors face toward the outer side of the heater NOTE Full side of deflectors face to the center of the heater...

Page 20: ...Page 20 1408 Quadradiant Align tabs of deflectors with slots on heater and insert tab into slots completely so that deflectors are flush against the unit...

Page 21: ...4308 Quadradiant Page 21 Using pliers bend the tabs to secure deflectors to the heater Bend these tabs toward the outer edge Bend these tabs toward the inside...

Page 22: ...l valve and burner assemblies Cover valve assembly with plastic before washing After wash downs remove plastic from heater We recommend that you light the heaters to dry up any excess moisture For pro...

Page 23: ...120V 5P NAT 16550105 CONTROL ASM QDR 120V 5P LP See pages 26 27 for components 1 each 16050044 IGNITOR w BURNER MOUNT WIRE 1 each 16550086 SPACER BURNER INNER CONE SHORT 2 each 16550038 HEAT DEFLECTOR...

Page 24: ...nt 16550081 CENTER SUPPORT CANOPY 1 each 16550080 END PLATE CONTROL END 1 each 16550079 END PLATE OPPOSITE CONTROL END 1 each 16550015 CANOPY 1 each 16550082 BOTTOM FLAME SHIELD 1 each 16550085 PAN CH...

Page 25: ...5 16550093 BURNER ASM 1 each 16050046 INSULATION BOTTOM PANEL 1 each 16050047 INSULATION SIDE PANEL 2 each 16050048 INSULATION 2 each END PANEL 16550084 EMITTER PANEL QDRII 16550089 INNER CONE CORRUGA...

Page 26: ...ach 16550091 HEAT SHIELD IGNITION CONTROL 1 each 16550083 BOX IGNITION CONTROL QDR II 1 each 16550055 CONTROL BOX LID QDR 1 each 10106615 HEYCO STRAIN RELIEF SR 7K 2 1 each 16050055 HOSE GAS 1 4ID 3 8...

Page 27: ...TCH TOGGLE SINGLE POLE 1 each 16050049 MODULE IGNITION 120V BENNI 1 each 16000058 VALVE ASCO 120V 5PSI 1 each 16550087 AIR INTAKE NAT QDR 16550088 AIR INTAKE LP QDR 16050051 WIRE HARNESS 1 each PARTS...

Page 28: ...1000683 BSHG 3 8 FPT X 1 2 MPT 1 3 13005228 PIPE NPL 1 2 CLOSE BLK 1 4 13004937 VALVE 1 2 BRASS BALL 1 5 13005193 PIPE NPL 1 2 X 3 BLK 1 6 13005229 PIPE CAP 1 2 BLK 1 Also included in the drip leg par...

Page 29: ...4308 Quadradiant Page 29 120 VOLT WIRING DIAGRAM...

Page 30: ...onsistent with excessive additions of chemicals minerals sediments or other foreign elements with the product shall not be considered defects under the Warranty 5 This Warranty applies only to systems...

Page 31: ...4308 Quadradiant Page 31 N NO OT TE ES S...

Reviews: