4308 Quadradiant
Page 11
SUSPENDING THE HEATER
NOTE:
We recommend that the heater be installed level. Keep gas hose away from hot surfaces.
The heater is attached to a winch cable used for raising and lowering.
In addition, a safety cable or chain (not supplied) is required to be attached to the
suspension hooks to prevent the heater from falling to the litter if the cable should happen to
break.
HEATER SAFETY CLEARANCE
The heater must be located so there is a minimum clearance to combustible material of 24"
(minimum of 12” if heat deflectors are used) above the heater and 48" from the side.
The heater should be hung with a min. of 72" from the bottom of the heater to the floor.
We require a minimum clearance of 12” from the heater to the fuel supply line.
The installer
MUST
comply with all applicable local, state, and federal gas codes and regulations for
your area.
Always allow heater to cool off before winching unit up to ceiling!
Materials that come in close proximity to hot surfaces may ignite.