background image

 

 

 

 

 

 

1101 

Housing  upper  section  cream  white 

1102 

Housing upper section grey 

1104/500 Housing upper section anthracite 
1131 

Suction grid cream white (2)

 

1132 

Suction grid grey (2)

 

1134 

Suction  grid  anthracite (2) 

1141 

Exhaust  grid  cream  white 

1142 

Exhaust grid grey 

1144/500 Exhaust grid anthracite 
1149 

Filter replacement plate

 

1150 

"Fill here" label

 

1151 

Filler flap cream white

 

1152 

Filler flap grey

 

1154 

Filler flap anthracite

 

1201 

Housing  lower  section  cream  white 

1202 

Housing lower section grey 

1204/500 Housing lower section anthracite 
1251 

Locating cover (4)

 

1252 

Guide pulleys (4)

 

1301 

Centre plate  cream  white 

1302 

Centre plate grey 

1304/500 Centre plate anthracite 
1309 p 

Armature plate

 

1311 

Shaft 

1312/500    Shaft cover

 

1326 

Electrode rods (set of 7) with head 

1339 

Cable loom

 

1347 p 

Base  circuit board

 

1348/3 

Measurement/transmission module 
complete with housing, without batteries

 

1348/4 

Battery 1,5 V AA (2)

 

1350 

Cover Box

 

1351 

Tensile strain reducer

 

1352 

Terminal block

 

1353 

Power cable with plug

 

1355 

Cable 0.8 m

 

1356 

Cable 0.8 m with socket 

1362 

"Withdraw mains plug" plate 

1369 

keypad foil

 

1401 

Water  distribution

 

1402 

Stick-on part extension (left) 

1403 

Stick-on  part  extension  (right) 

1406 

Remote control

 

1411 

Filter rods without grooves (6)

 

1412 

Filter rods with grooves (4)

 

 

1413

 

Clamp-bracket with double-nib

 

1500

 

Fan complete with  motor, housing and

 

 

1507

 

mounting parts 
Fan housing

 

1508

 

Sheet metal screw M 4,2 x 19 A2 (4)

 

1518

 

Plug body with cable

 

1520

 

Gum-metal bumper M 4

 

 

1522/1

 

High Quality steel (3)

 

Pump motor incl. 0.3 m  cable and

 

 

1523

 

pump ventilator 
Pump body

 

1524

 

Pump cover

 

1525

 

Pump  impeller  blade

 

1526

 

Y-shaped piece

 

1529

 

Pump hose clear (2)

 

1551

 

Cylinder head screw M 4 x 10

 

1552

 

Cylinder head screw M 4 x 12

 

1553

 

Cylinder head screw M 4 x 6

 

1555

 

Countersunk screw M 4 x 10

 

1556

 

Cap nut M 4

 

1561

 

Brass nut M 4

 

1565

 

Toothed disk M 4

 

1566

 

Washer M 4

 

1567

 

Washer V2 M 5 x 15

 

1568

 

Poly washer M 5 x 15

 

1603

 

Bio-filter B 500

 

*Optional  extras  and  accessories

 

1605/500  Charcoal-Filter-Set

 

1720

 

UV-C-technology

 

1721

 

6-Watt  spotlight (UV germicide)

 

1725

 

Lime transformation cartridge

 

1740

 

Rinsing  system, complete

 

1741

 

Pump  for  rinsing  system

 

1747

 

Drainage hose for rinsing

 

1752

 

Safety collecting tub

 

1753

 

Water filling control system

 

1754

 

Safety pressure hose

 

1757

 

Safety water  sensor

 

1798

 

Magnetic  valve, complete

 

1799

 

Automatic  water  supply,  complete

 

21. Parts list

 

Summary of Contents for B500

Page 1: ......

Page 2: ...gy with calcium conversion cartridge B 14 Changing the UV tubes B 14 21 Parts list B 15 22 Design Exploded view drawing B 16 23 Maintenance check lists B 17 24 Correcting faults B 19 25 Installation suggestions B 20 26 Technical d a t a B 21 m Before you commission your new equip ment please read through the operating in structions Commissioning Check List Within the equipment are the accessories ...

Page 3: ...er change indicator Electronic water level indicator Fan speed indicator Automatic fan Actual required atmospheric humidity dis play Menu in programming mode or Fault code with error message Error message display note fault code The electronic hygrostat radio sensor system auto matically controls the humidifier The required humid ity values can be set by means of the remote control m Disconnect th...

Page 4: ...r level is indicated by light emitting diodes max 5 stages Both normal tap water and softened water can be used to operate the humidifier m Do not use distilled water Take care to fill correctly since spilt water could enter the equipment and cause a short circuit The maximum temperature of the water must not exceed 35 C The water level is sensed by copper electrodes and is indicated by LEDs on th...

Page 5: ...n of the housing thus causing leaks m Before doing any work on the appliance always make sure it is unplugged from the wall socket In the event of a defect in the control panel it may be necessary to replace it completely Please proceed as follows 1 Raise the upper part of the housing 2 Loosen the four screws on the corners of the con trol panel and take the panel out 3 Unplug the plugs 1 2 X9 vfr...

Page 6: ... its own speed depending on the output required It does this by measuring the changes in atmospheric humidity and increasing or decreasing the fan speed accordingly To activate the automatic fan press the side of the Fan button and hold it down until the last bar has disappeared from the indicator and the red diode with the fan symbol has gone out To deactivate it simply increase the fan speed wit...

Page 7: ...toryadjusted to 2 14 Coding the radio sensor system Coding the sensor These appliances are coded in the factory but if two or more are used in direct proximity to one another i e less than 50 metres apart a different coding may be necessary For each slide control there are only two positions ON up and 0FF down which give 16 possible combinations Please note each appliance and its ra dio sensor a b...

Page 8: ...s setting yourself Please refer to the section on Menu programming The following fault codes tell you what problem has occurred and what has to be done m If a fault code is displayed only the On Off button and the PROG and SET key on the re mote control unit can be used Fault code Fault What to do 01 Water tank is empty Check water level and top up if necessary Check water level diodes for dirt an...

Page 9: ...ve humidi ty The programming process can be termi nated at any time by pressing the ON OFF button Please note however that this will result in the loss of all the changes that have been made 10 Hooter setting 11 Hooter active when tank 00 OFF empty 01 ON 01 12 Hooter active when UV 00 OFF Only at version with lamp is defective 01 ON UV C technology 01 13 Hooter active with external 00 OFF With ext...

Page 10: ... switch or other 230V 01 ON switching mechanism REQUIRED humidity level is fixed at 90 The ACTUAL display shows a constant 00 rF The fan can be set freely at any suitable speed 00 35 Setting Changing interval of the fan in auto mode 01 10 min Dependent on the size of the room The immersion pump can be removed from the centre plate by turning it in the direction indicated by the arrow Take particul...

Page 11: ...ection to the local water main must be made by a qualified specialist i e a licensed installation tech nician Please note the water supply utility s regula tions It may be advisable to fit a back flow stop valve We recommend our 1 5 metre long safety pressure hose for the connection between the water pipe and the appliance Product no 1754 The automatic sys tem for topping up the water incorporates...

Page 12: ...ly removed from the clips The service life is approx 6 months which primarily depends on the dirt in the room air e g smoke and dust accumulation Air scoop with flexible hose These accessories are especially used in church or gans The scoop is fitted or screwed to the outlet of the B 500 Provided with a flexible aluminium ventila tion hose 150 mm which carries the humidified air into the critical ...

Page 13: ...perly and insert it into the glass tube again with care The UV lamp is to be disposed of in accordance with legal requirements The UV tube has an operating life of about 5000 hours m Please take care that the quartz glass body in which the source sits is not damaged when fitting and removing the UV source All accessories can be retrofitted at any time at the factory or by an authorised dealer m In...

Page 14: ...ypad foil 1401 Water distribution 1402 Stick on part extension left 1403 Stick on part extension right 1406 Remote control 1411 Filter rods without grooves 6 1412 Filter rods with grooves 4 1413 Clamp bracket with double nib 1500 Fan complete with motor housing and 1507 mounting parts Fan housing 1508 Sheet metal screw M 4 2 x 19 A2 4 1518 Plug body with cable 1520 Gum metal bumper M 4 1522 1 High...

Page 15: ...22 Construction ...

Page 16: ... residues such as lime or dust for instance by means of a needle a screwdriver or even use a vacuum cleaner for this Lift middle part of device off in upward direction Remove remaining water from the water container and clean the tub bottom part This is necessary in particular when using fresh water in order to avoid higher concent rations of residues Visual check of the copper electrode bars see ...

Page 17: ... cartridge Lift the centre plate upwards out of the water tank lower part The UV degermination arrangement is located below the centre plate next to the pump Inspect stainless steel tube visually and remove fouling Withdraw pump hoses from the stainless steel tube and check the passage of the stainless steel tube hoses Remove fouling Take care that the quartz glass body is not damaged The lime con...

Page 18: ...ectly installed Renew filter Check the filter seating Water degermination moni tor lamp does not light 1 UV source defect Replace UV source Device does not respond to the remote control Battery discharged or incorrectly installed Distance between remote control and device too great Check battery and replace note Reduce distance Automatic water feed no longer replenishes water 2 Safety pressure hos...

Page 19: ... must be taken to ensure that adequately large openings are available for air intakes and outlets to ventilate the appliance Living room area Equipment in a specialist shop walk in humidor Possible uses in the museum area or in churches to protect valuable organs 25 Installation suggestions ...

Page 20: ...ent Air flow capacity 900 m h Evaporation capacity 2 6 ltr h on 25o C and 20 r H Evaporation filter area 3 5 m Weight empty approx 24 kg Water reservoir approx 50 ltr Dimensions L 75 5 x H 62 0 x W 36 5 cm m Disconnect the mains plug before openingthe equipment 26 Technical data ...

Reviews: