background image

 

3

 

Important Notes 



The ecoFAN™ is designed for general household ventilation only. DO 
NOT use to exhaust hazardous or explosive materials and vapours. 



One side of the ecoFAN™ has an unguarded fan assembly. DO NOT 
use in locations that expose the unguarded side to areas readily 
accessible to people or animals. 



Always use the provided power supply and speed controller to power 
the fan. Failure to do so can damage the product. 



Ensure that the power supply and speed controller are not left on 
damp surfaces, fasten to available structure with cable ties if 
required. 



Only use one ecoFAN™  per speed controller and power supply. 

 

Important Notices and Warnings 

WARNING: Do not proceed with the installation until you have read the 
entire instructions, including these warnings. 

Install at your own risk 

The installation of this product may be dangerous and includes the 

potential of personal injury or property damage. Please take care when 

installing this product and be mindful of risks. Please be aware of the 
following when installing this product. 



Installation requires the cutting and removal of bricks.  This process 

can produce airborne debris and other hazards. To minimise risks 

wear personal protection equipment such as appropriate eye 
protection, gloves and a dust mask. 



When selecting a location for the ecoFAN™ make sure that the area 
is clear of services such as pipes and power cables. 

Summary of Contents for Edmonds

Page 1: ...Product Manual...

Page 2: ...ct Drill 6mm Masonry Drill Bit Screwdriver with Phillips P2 Bit Marker Pen Cable Ties Included Parts QTY 1 ecoFAN 1 2 Speed Controller 1 3 Power Supply 1 5 6mm Wall Plugs 4 6 8Gx32mm CSK Screws 4 7 Pr...

Page 3: ...controller and power supply Important Notices and Warnings WARNING Do not proceed with the installation until you have read the entire instructions including these warnings Install at your own risk Th...

Page 4: ...g as a guide mark out a circle location on the wall Installation STEP 2 Option A Using an impact drill and 6mm drill bit Drill holes spaced 3 4 cm around the marked perimeter Using a hammer carefully...

Page 5: ...5 STEP 3 Clear the hole of debris Installation STEP 2 Option B Remove the complete top and bottom shaded bricks Cut and remove the middle shaded bricks...

Page 6: ...m masonry bit drill mounting holes as marked previously STEP 4 Insert the ecoFAN into the hole Make sure it is level and the correct way up Mark the positions of the mounting holes The back of the wal...

Page 7: ...7 STEP 6 Insert supplied wall plugs into the 6mm drilled mounting holes Tap into hole with hammer until flush Installation STEP 7 Using the supplied screws screw the ecoFAN into the wall plugs...

Page 8: ...y cable STEP 3 Connect the power supply to a mains socket Turn on and check ran funs freely STEP 4 Using either the screws supplied or cable ties mount the speed controller and the power supply in a s...

Page 9: ...osition is LO MODES LO Default Continuous operation low speed low flow rate very quiet very low power consumption MED Continuous operation moderate speed moderate flow rate HI Continuous operation hig...

Page 10: ...crews fixing the fan housing to the wall grille There are arrows on the motor housing that indicate the direction of airflow STEP 2 Reverse the fan housing and using the same screws mount the housing...

Page 11: ...all grille STEP 2 Paint wall grille and allow to dry Reattach the wall grille to the fan housing using the screws removed earlier Step 1 in reverse The plastic used for the wall grille is suitable for...

Page 12: ...an Motor Electronic Commutating EC motor Internal Voltage 24 VDC Protection Class IP54 Speed Control Type Temperature Sensing Electronic Variable Speed Controller Input Voltage 24 VDC Fixed Speed Oper...

Page 13: ...Product Dimensions Speed Sound Pressure Level SPL LA psF 0 dB A Max running power consumption W Flow rate qv psF 0 m3 hr LO 32 8 4 4 280 MED 43 11 6 457 HI 53 5 30 734 NOTE Sound pressure level measur...

Page 14: ...required to install one Q Can I wire it directly into the mains power A No you must use the supplied power supply and speed controller for the ecoFAN to work correctly Failure to do so may damage the...

Page 15: ...g Products Limited ABN 55 008 631 356 10 Stanton Road Seven Hills NSW 2147 Australia www edmonds com au Contact Details General Enquiries and Support PH 1300 858 674 Email Sales edmonds com au Technic...

Page 16: ......

Reviews: