Signature 2
Series
pg. 4
Starting Extra Regeneration Cycle
1. To Start Delayed Extra Cycle
Example [ 1 ]
- If Days Remaining Until Next Regeneration does not read ‘1’, press and hold the
Set/Change button for 3 seconds until the display reads ‘1’, or ‘0000’ on metered models.
-
Regeneration cycle will initiate at the next designated regeneration time.
2. To start Immediate Extra Cycle
First complete above step.
- With Days Remaining Until Next Regeneration at ‘1’ or ‘0000’,
- Press and hold the Set/Change button.
- After 3 seconds, the regeneration cycle will begin.
3. To Fast Cycle thru regeneration
First complete above 2 steps.
Note: Fast Cycle is not necessary unless desired to manually step through each cycle step.
-
Press and hold the Set/Change button for 3 seconds to advance to the next cycle step.
Softeners
Default (min.)
Filters
Default
(min.)
Step 1 : Backwash
10
Step 1 : Backwash
10
Step 2 : Brine & Rinse
60
Step 2 : Rest
5
Step 3 : Rapid Rinse
10
Step 3 : Rapid Rinse
10
Step 4 : Brine Refill
Set for full salting
Step 4 : Not Used
0
Nitro
Default (min.)
Nitro Pro
Default
(min.)
Step 1 : Air Release
6
Step 1 : Air Release
6
Step 2 : Backwash
10
*Step 2 : Oxyclean NP Injection
15 sec.
Step 3 : Rest
5
Step 3 : Short Rinse
1
Step 4 : Air Replenish
12
Step 4 : Rest
20
Step 5 : Rapid Rinse
10
Step 5 : Backwash
10
Step 6 : Rest
5
Warning: On NITRO PRO System, if “J”
Program is used, the Oxyclean NP must be
used to avoid any warranty issues.
Step 7 : Air Replenish
12
Step 8 : Rapid Rinse
10
Note: Depending upon system pressure
and other factors, it is possible to observe
flow to drain in the rest cycles.
*Only if “J” program (Oxyclean NP Option) is
activated.
Summary of Contents for LV-019
Page 12: ...Signature 2 Series pg 12 Control Valve Assembly Nitro Nitro Pro ...
Page 13: ...Signature 2 Series pg 13 NITRO NITRO PRO BODY ASSEMBLY ...
Page 15: ...Signature 2 Series pg 15 Control Valve Drive Assembly Filter Version ...
Page 17: ...Signature 2 Series pg 17 Control Valve Assembly Softener Version ...