Page 12
Digital Display Center (DDC)
Installation
To install the DDC, remove the faceplate from above the
control center on the subdoor and insert the DDC module
from the back of the subdoor. Next, screw in the four
corner screws.
With the power off
, attach the ribbon from
the DDC module to the control board. After everything is
installed, turn the power on. It may take up to 10 seconds
for the circuit board to complete the program update.
Once the circuit board has completed the program
update, normal operation will begin.
Note:
RKE boards cannot update through the DDC.
Display Menu
Press Menu/Enter Button to change between menu
fields
Et. #
- (Elapsed Time, # is Pump number (1 or 2)):
Reads out the total elapsed run time of the corresponding pump.
Press Set/Change button to alternate between
hours and minutes & seconds
CC.#
- (Cycle Counter, # is Pump number (1 or 2)):
Reads out the number of cycles the corresponding pump has
run. (Max Value: 9999)
F1tr
- (Field 1 Timer, Time Dose DDCs only):
Reads out the remaining time in the current time cycle. If the
pump(s) are running then it indicates the time remaining until the
pump(s) shut off. If the pump(s) are off then it indicates time
remaining until the pump(s) are enabled to run again.
Installation Screws
Back of DDC Module
Connecting Ribbon
Menu/Enter
Button
Set/Change
Button
dEPH
MENU
ENTER
SET
CHANGE
Make sure power is OFF before installing DDC!
RK Series
™
Removable Face Plate
Installation Screws