IRGASON
®
Integrated CO
2
/H
2
O Open-Path Gas Analyzer and 3D Sonic Anemometer
4
Sonic accuracy
5
Offset error
u
x
, u
y
:
< ±8 cm
·
s
–1
u
z
:
< 4 cm
·
s
–1
Gain error
Wind vector ±5° horizontal:
< ±2% of reading
Wind vector ±10° horizontal:
< ±3% of reading
Wind vector ±20° horizontal:
< ±6% of reading
Sonic reporting range
Full scale wind:
±65.553 m/s
Sonic temperature:
–50 to 60 °C
Auxiliary sensors
6
Barometer
Basic barometer
Accuracy
–30 to 0 °C:
±3.7 kPa at –30 °C, falling linearly to ±1.5
kPa at 0 °C
0 to 50 °C:
±1.5 kPa
Measurement rate:
10 Hz
Optional enhanced barometer:
Manufacturer:
Vaisala
Model:
PTB110
Accuracy
–30 to 0 °C:
±0.15 kPa
Measurement rate:
1 Hz
IRGASON temperature sensor:
Manufacturer:
BetaTherm
Model:
100K6A1A Thermistor
Accuracy:
±0.15 °C (–30 to 50 °C)
1
noise rms, assumes:
o
25 °C
o
85 kPa
o
14 g·m
–3
H
2
O
o
597 mg·m
–3
CO
2
o
25 Hz bandwidth.
2
user selectable
3
–30 to 50 °C
4
noise rms
5
assumes:
o
–30 to 50 °C
o
wind speed <30 m·s
–1
o
azimuth angles between ±170°
6
refer to manufacturer’s product brochure or manual for details
Summary of Contents for IRGASON
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 12: ...Table of Contents iv ...
Page 60: ...Appendix A Filter Bandwidth and Time Delay A 4 ...
Page 64: ...Appendix C Material Safety Data Sheets MSDS C 2 ...
Page 65: ...Appendix C Material Safety Data Sheets MSDS C 3 ...
Page 66: ...Appendix C Material Safety Data Sheets MSDS C 4 ...
Page 67: ...Appendix C Material Safety Data Sheets MSDS C 5 ...
Page 68: ...Appendix C Material Safety Data Sheets MSDS C 6 ...
Page 69: ...Appendix C Material Safety Data Sheets MSDS C 7 ...
Page 70: ...Appendix C Material Safety Data Sheets MSDS C 8 C 2 Decarbite MSDS ...
Page 71: ...Appendix C Material Safety Data Sheets MSDS C 9 ...
Page 72: ...Appendix C Material Safety Data Sheets MSDS C 10 ...
Page 73: ......