27 Bank Street Meadowbank NSW 2114 Australia
Tel: +61 2 9809 0588 Fax: +61 2 9809 2446 email: [email protected]
iKey Interface
CS Controller and Software Configuration
Wiegand Format:
CONTROLLER:
Set appropriate controller links
LK19, LK18, LK17, LK8, LK20 – OFF
LK21 – DOWN, LK22 – UP (+V = 5 volts)
Reader on Port 1:
LK20 ON
Reader on Port 2:
LK19, LK18 - ON
Reader on Port 3 &/or 4:
LK17, LK8 – ON
SOFTWARE:
Set the controller type as ‘CARD’.
Set the reader type as ‘WIEGAND’.
Clock + Data Format:
CONTROLLER:
Set appropriate controller links
LK19, LK18, LK17, LK8, LK20 – OFF
LK21 – DOWN, LK22 – UP (+V = 5 volts)
Reader on Port 1:
no link changes
Reader on Port 2:
LK19 - ON
Reader on Port 3 &/or 4:
LK17 – ON
SOFTWARE:
Set the controller type as ‘CARD’.
Set the reader type as ‘CLOCK + DATA’.
Set the magstipe card parameters as shown below and tick
‘Wiegand type sitecode and card number’
(‘Hardware/Site/Edit Card Option’)