CS Instruments 0500.0009 Instruction Manual Download Page 9

 

V1.06 EN 

 

13.  Calibration/adjustment

 

 

At CS Instruments

 

According to DIN ISO certification of the measuring instruments we recommend to 
calibrate and if applicable to adjust the instruments regularly at the manufacturer. 
The calibration intervals should comply with your internal specification. According to 
DIN ISO we recommend a calibration interval of one year for the instrument DS 52 
including probes. 

 
14.  Warranty 

 
If you have reason for complaint, we will of course repair any faults free of charge if it 
can be proven that they are manufacturing faults. The fault should be reported 
immediately after it has been found and within the warranty time guaranteed by us. 
Excluded from this warranty is damage caused by improper use and non adherence 
to the instruction manual. 
 
The warranty is also cancelled once the instrument has been opened - as far as this 
has not been mentioned in the instruction manual for maintenance purposes - or if 
the serial number in the instrument has been changed, damaged or removed.   
 
The warranty time for DS 52 is 12 months; the warranty time of the accessories is 6 
months. Warranty services do not extend the warranty time. 
 
If in addition to the warranty service necessary repairs, adjustments or similar are 
carried out the warranty services are free of charge but there is a charge for other 
services such as transport and packaging costs. Other claims, especially those for 
damage occurring outside the instrument, are not included unless responsibility is 
legally binding. 
 

After sales service after the warranty time has elapsed

 

We are of course there for you even after the warranty time has elapsed. In case of 
malfunctions, please send us the instrument with a short-form description of the fault. 
Please do not forget to indicate your telephone number so that we can call you in 
case of any questions. 
 
 

Summary of Contents for 0500.0009

Page 1: ...V1 06 EN 1 Instruction Manual Digital Display DS 52 in wall housing Order no 0500 0009 for 0 4 20 mA sensors...

Page 2: ...dard products every year There are a few good reasons for doing so The cost performance ratio reliable quality at a fair price We have the ideal solutions for your measuring tasks based on our expert...

Page 3: ...the delivery capability or use of this device Initiation electrical connection When operating electrical instruments it is unavoidable that certain components are energised dangerously Work at electri...

Page 4: ...nd alarm connection Pinning Supply 13 14 15 110 VAC 230 VAC PE N L 24V dc 24 V 10 1 Connection of CS Instruments sensors Supply 110VAC 230 VAC 50 60 Hz 24 V DC Attention Mains voltage NC und COM are c...

Page 5: ...nsor Terminal connector M12 7 8 9 101112131415 1 2 3 4 5 6 Sensor Supply A1 2 A1 1 PE N L V GND I I I SIG 1 2 3 4 5 FA 515 Braun brown Blau blue CS Sensor Terminal connector M12 A bridge circuit is in...

Page 6: ...llows 2 3 Connection option alarm unit 7 8 9 101112131415 1 2 3 4 5 6 Sensor 230 VAC A1 2 A1 1 PE N L V GND I I I SIG 0 1 2 5 4 3 Netzanschlussleitung Supply cable gr n gelb green yellow blau blue bra...

Page 7: ...2 nOr alters press shortly HY 2 2 0 alters press shortly rEv rEv With alarm threshold 1 scaling up with scaling down nOr Normal means Alarm 1 in case of threshold exceeding rEv Reverse means Alarm 1 i...

Page 8: ...with and whether you want to connect a sensor with 0 20 mA signal or with 4 20 mA signal 4 mA 0 20 mA 500 With and you can set the lower scaling value 4 mA resp 0 mA of your sensor With and you set t...

Page 9: ...instrument has been opened as far as this has not been mentioned in the instruction manual for maintenance purposes or if the serial number in the instrument has been changed damaged or removed The wa...

Page 10: ...yfuse max 100 mA Voltage supply 230 V 50 60 Hz Outputs 2 x relays output changer 250 VAC max 3 A Operation temperature 10 C 60 C storage temperature 20 C 80 C Alarm thresholds freeley adjustable Hyste...

Page 11: ...ee Tel 49 0 461 80 71 50 00 Fax 49 0 461 80 71 50 15 E Mail info cs instruments com www cs instruments com m Sales Office South CS Instruments GmbH Co KG Zindelsteiner Stra e 15 78052 VS Tannheim Tel...

Reviews: