15.  Technical data 

 

Housing dimensions 

118 mm x 92 mm x 133 mm 

Display 

LED red, 7 segments, height: 13 mm, 5 digits, 2 LED for 
switching outputs (alarm relays) 

Keypad 

4 keys: Enter, Back, Up, Down 

Sensor input 

1 x analogue input for sensors with 0…20 mA or  
0/4…20 mA signal. Connectable in 2-/3- or 4-wire- 
technologie possible with 24 VDC supply 

Burden analogue input 

100 Ohm 

Accuracy analogue 
input 

max. < 

±

 20 µA, typical 10 µA 

Sensor supply 

24 VDC with Polyfuse max. 100 mA 

Voltage supply 

230 V, 50/60 Hz 

Outputs 

2 x relays output, changer, 250 VAC, max. 3 A 

Operation temperature  -

10 °C…+60 °C (storage temperature: -20 °C…+80°C) 

Alarm thresholds 

freeley adjustable 

Hysteresis 

2 °Ctd 

 
 
16.  Order information 
 

Description 

Order no. 

DS 52 - LED display in wall housing (118 x 92 x 133 mm), 
Supply: 230 V. Analogue sensor input for sensors with 
4…20 mA or 0…20 mA signals. 2 alarm relays (change-over 
contact 250 VAC, max. 3 A), alarm values freely adjustable 
 

 
0500 0009 

Options 

 

Option for DS 52 LED display: Supply 24 VDC instead of 
230 VAC, 50/60 Hz 

 
Z500 0001 
 

Option for DS 52 LED display: Supply 110 VAC instead of 
230 VAC, 50/60 Hz 

 
Z500 0002 
 

 

Summary of Contents for 0500.0009

Page 1: ...V1 06 EN 1 Instruction Manual Digital Display DS 52 in wall housing Order no 0500 0009 for 0 4 20 mA sensors...

Page 2: ...dard products every year There are a few good reasons for doing so The cost performance ratio reliable quality at a fair price We have the ideal solutions for your measuring tasks based on our expert...

Page 3: ...the delivery capability or use of this device Initiation electrical connection When operating electrical instruments it is unavoidable that certain components are energised dangerously Work at electri...

Page 4: ...nd alarm connection Pinning Supply 13 14 15 110 VAC 230 VAC PE N L 24V dc 24 V 10 1 Connection of CS Instruments sensors Supply 110VAC 230 VAC 50 60 Hz 24 V DC Attention Mains voltage NC und COM are c...

Page 5: ...nsor Terminal connector M12 7 8 9 101112131415 1 2 3 4 5 6 Sensor Supply A1 2 A1 1 PE N L V GND I I I SIG 1 2 3 4 5 FA 515 Braun brown Blau blue CS Sensor Terminal connector M12 A bridge circuit is in...

Page 6: ...llows 2 3 Connection option alarm unit 7 8 9 101112131415 1 2 3 4 5 6 Sensor 230 VAC A1 2 A1 1 PE N L V GND I I I SIG 0 1 2 5 4 3 Netzanschlussleitung Supply cable gr n gelb green yellow blau blue bra...

Page 7: ...2 nOr alters press shortly HY 2 2 0 alters press shortly rEv rEv With alarm threshold 1 scaling up with scaling down nOr Normal means Alarm 1 in case of threshold exceeding rEv Reverse means Alarm 1 i...

Page 8: ...with and whether you want to connect a sensor with 0 20 mA signal or with 4 20 mA signal 4 mA 0 20 mA 500 With and you can set the lower scaling value 4 mA resp 0 mA of your sensor With and you set t...

Page 9: ...instrument has been opened as far as this has not been mentioned in the instruction manual for maintenance purposes or if the serial number in the instrument has been changed damaged or removed The wa...

Page 10: ...yfuse max 100 mA Voltage supply 230 V 50 60 Hz Outputs 2 x relays output changer 250 VAC max 3 A Operation temperature 10 C 60 C storage temperature 20 C 80 C Alarm thresholds freeley adjustable Hyste...

Page 11: ...ee Tel 49 0 461 80 71 50 00 Fax 49 0 461 80 71 50 15 E Mail info cs instruments com www cs instruments com m Sales Office South CS Instruments GmbH Co KG Zindelsteiner Stra e 15 78052 VS Tannheim Tel...

Reviews: