6
LiPo/LiIo/LiFe , CHK Time 10min
To avoid from erroneous setting by users, the CS-Professional X2 Charger
detects the cell count of Lithium battery automatically at the beginning
of charge or discharge process. But battery that is deep-discharged can’t
be detected correctly. To avoid this error, the time term can be set to
verify the cell count by the processor. Normally, 15 seconds are enough
to detect the cell count correctly. You need to extend the time term limit for the
battery of large capacity. But the charge or discharge process may come to an
end within the time term because of the time limit decided by the wrong count if you set too
long time limit for the battery of small capacity. This may cause fatal error. You have to extend
the time term if the processor detect the cell count incorrectly at the beginning of charge or
discharge process. Otherwise, default value of 10 minutes is recommended to use.
To change the factory setting of 10 minutes press the enter key and change the flashing value
with the -DEC/+INC-keys. Safe the set value with the enter key.
To go on with the basic setting press the -DEC/+INC-keys:
NiMH Sensitivity / D.Peak Default:
This shows the trigger voltage for the automatic charge termination of
a NiMH battery. The valid value ranges from 5 to 20 mV per cell. Setting
the trigger voltage higher brings a danger of overcharging; whereas
setting it lower brings a possibility of premature termination. Please
refer to the technical specification of the battery. The factory default is
set to 7mV.
To change the factory setting of 7mV press the enter key and change the
flashing value with the -DEC/+INC-keys. Safe the set value with the enter key.
To go on with the basic setting press the -DEC/+INC-keys:
NiCd Sensitivity / D.Peak Default:
This shows the trigger voltage for the automatic charge termination of
a NiCd battery. The valid value ranges from 5 to 20 mV per cell. Setting
the trigger voltage higher brings a danger of overcharging; whereas
setting it lower brings a possibility of premature termination. Please
refer to the technical specification of the battery. The factory default is
set to 12mV.
To change the factory setting of 12mV press the enter key and change the
flashing value with the -DEC/+INC-keys. Safe the set value with the enter key.
To go on with the basic setting press the -DEC/+INC-keys:
USB/TEMP/SELECT / TEMP Cut-Off 80C:
There is a 3-pin port on the left of the charger used as USB interface
or temperature sensor port (both is optional available). When using
the temperature sensor (#C140202) you have to set here the tempe-
rature limit. This can be set from 20 to 80°C. If the battery reaches this
temperature, the charging process will be terminated. Only for charger
1 and 2.
To change the factory setting of 80°V press the enter key and change the flashing
value with the -DEC/+INC-keys. Safe the set value with the enter key.
To go on with the basic setting press the -DEC/+INC-keys: