Crystal Vision
Installation
SW808 User Manual R1.8
32
22/12/2008
GPI connections
4U frame GPI Connections
GPI lines ‘a’ to ‘f’ of each card connect to one of eight rear remote connectors as follows:
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
4
7 (3)
16 (3)
17 (3)
25 (3)
10 (4)
11 (4)
6
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
8
4 (3)
14 (3)
13 (3)
23 (3)
3 (4)
4 (4)
10
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
12
10 (3)
11 (3)
19 (3)
20 (3)
21 (4)
22 (4)
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
2
7 (5)
16 (5)
17 (5)
25 (5)
10 (6)
11 (6)
4
7 (7)
16 (7)
17 (7)
25 (7)
10 (8)
11 (8)
6
4 (5)
14 (5)
13 (5)
23 (5)
3 (6)
4 (6)
8
4 (7)
14 (7)
13 (7)
23 (7)
3 (8)
4 (8)
10
10 (5)
11 (5)
19 (5)
20 (5)
21 (6)
22 (6)
12
10 (7)
11 (7)
19 (7)
20 (7)
21 (8)
22 (8)
Table shows pin number (Remote number)
Note:
Remote 1, Remote 3, Remote 5 and Remote 7 are 26 way high density D-Type female
sockets and frame ground is pin 2 and +5V @500mA is pin 1 in each case.
Remote 2 and Remote 4 are 26 way high density D-Type male plugs and frame ground is
pin 6 and +5V @500mA is pin 15 in each case.
Upper
Lower