Crystal Vision
Rear modules and signal I/O
Rear module connections with RM57
The RM57 being a single height module will allow maximum packing density with one
HD/SD video input and three HD/SD video outputs and a single optical I/O connector.
RM57 rear module connector
Description
RM57
•
12 per Indigo 2 frame
•
Six per Indigo 1 frame
•
Two per Indigo DT
•
All frame slots can be used
BNC connections
BNC
I/O assignment
HD/SD IN
3G/High Definition/Standard Definition serial digital input.
NC
No connection
HD/SD OUT 1
3G/High Definition/Standard Definition serial digital output.
HD/SD OUT 2
3G/High Definition/Standard Definition serial digital output.
HD/SD OUT 3
3G/High Definition/Standard Definition serial digital output.
OPTICAL IN/OUT
3G/High Definition/Standard Definition serial digital optical input/output.
Rear module connections with RM67
The RM67 relay bypass rear module is a single height module that allows maximum
packing density with one HD/SD video input and four HD/SD video outputs. In the
event of power failure, the video input is automatically connected to HD/SD OUT 3
(SWITCHED).
RM67 rear module connector
Description
RM67
•
12 per Indigo 2 frame
•
Six per Indigo 1 frame
•
Two per Indigo DT
•
All frame slots can be used
ViViD 3GT-20 User Manual R1.1
8