Crystal Vision
Control Descriptions
Presets, Resets And GPOs
Presets
Up to 16 user-defined configurations may be stored and recalled either from
VisionWeb or through the use of external GPIs. Presets store the board setup data
including operating mode card status.
Preset Select
Select from 1-16 which preset to store or
recall.
Store
Save the setup in preset memory 1-16.
Recall
Restore the selected preset.
GPI Enable
Select to recall previously saved presets via the external GPI port.
See section
GPIs.
GPI Trigger
Select either level or pulse to trigger GPI
recall.
GPI Level
Select either active low or high level to
trigger the GPI recall.
ViViD 3GT-20 User Manual R1.1
28