Up to 16 user-defined configurations may be stored and recalled either from the board control,
active front panel, Statesman or through the use of external GPIs. Presets store the board setup
data including operating mode card status. The presets are numbered 1-16.
Presets and factory reset
Note:
Care should be taken when storing presets that the desired configuration is not
changed by any external input prior to saving.
Saving and recalling presets
The current board settings can be saved in one of 16 locations to be recalled as desired. This
allows the user to store and recall up to 16 different configurations for later use.
To save the current settings, select the preset location and press Enter. This will write the current
settings into this location.