Crystal Vision
Using the front control panel
YUV threshold and level controls
Menu
Description
Levels menu
Press F2 from the home menu to view the levels menus.
Press F2 from the levels menu to view the YUV controls.
YUV levels
Press F1 from the YUV levels menu to view the YUV threshold
controls.
YUV threshold
(High)
Rotate the shaft control to view the YUV threshold (max clip).
Press F2 to select and rotate the shaft control to set the level.
90-110%.
YUV Clip
(High)
Rotate the shaft control to view the YUV clip (max clip).
Press F2 to select and rotate the shaft control to set the level.
Hard, Medium, Soft.
YUV threshold
(Low)
Rotate the shaft control to view the YUV threshold (min clip).
Press F2 to select and rotate the shaft control to set the level.
0
±
10%.
YUV Clip (Low)
Rotate the shaft control to view the YUV clip (min clip).
Press F2 to select and rotate the shaft control to set the level.
Hard, Medium, Soft.
C Threshold
Rotate the shaft control to view the C threshold.
Press F2 to select and rotate the shaft control to set the level.
90-100%.
C Clip
Rotate the shaft control to view the C clip.
Press F2 to select and rotate the shaft control to set the level.
Hard, Medium, Soft.
Black cleanup
Rotate the shaft control to view the Black Cleanup.
Press F2 to select and rotate the shaft control to set the level.
0-10%.
Y component gain
Rotate the shaft control to view the Y gain.
Press F2 to select and rotate the shaft control to set the level.
0-200%.
Y component lift
Rotate the shaft control to view the Y lift.
Press F2 to select and rotate the shaft control to set the level.
0
±
10%.
U component gain
Rotate the shaft control to view the U gain.
Press F2 to select and rotate the shaft control to set the level.
0-200%.
U component lift
Rotate the shaft control to view the U lift.
Press F2 to select and rotate the shaft control to set the level.
0
±
10%.
V component gain
Rotate the shaft control to view the V gain.
Press F2 to select and rotate the shaft control to set the level.
0-200%.
V component lift
Rotate the shaft control to view the V lift.
Press F2 to select and rotate the shaft control to set the level.
0
±
10%.
CoCo 3G User Manual R1.7
31
11 January 2021