Crystal Vision
Installation
5 Installation
Six different rear connector modules (RM) may be used with ADCA412. There are
single, dual and triple slot versions available offering a variety of I/O options and rack
population densities. Other Crystal Vision RM and Interface PCBs can be mixed in any
quantity with the ADCA412, up to a maximum of 24 PCBs, providing the other PCBs do
not exceed the power rating of the PSU chosen (normally 150 watts).
The available rear connectors are as follows:
Rear Connectors
Description
AES Out
ZLA00098 ADCA412 RM03
Analogue Audio In
1
25
1
15
RM03 – ZLA00098
•
24 modules per Indigo 4 frame
•
Recommended for 110 Ohm
balanced AES outputs and
AES Ref in
•
GPI lines also available at
frame remote connectors
•
All frame slots can be used
Audio Out
ZLA00093 RM11
1
26
Ref In
Audio In
15
1
RM11 – ZLA00093
•
24 modules per Indigo 4 frame
•
Recommended for 110 Ohm
balanced AES outputs and
video or word clock Ref in
•
GPI lines also available at
frame remote connectors
•
All frame slots can be used
RM13
•
12 modules per Indigo 4 frame
•
Recommended for 75 Ohm
unbalanced AES outputs
•
GPI lines only available at
frame remote connectors
•
Slots 1,3,5,7,9 and 11 used
Notes:
The RM11 is similar to the RM03, but has an additional BNC input for the reference
signals required for ADCA412 PCBs, and has a high density 26 way D-connector
instead of the standard 25 way D-connector. If the rack frame has a mixture of
DACA214 and ADCA412 PCBs, the user may wish to standardise on one common
RM11 for both DACA214 and ADCA412 board types.
The RM03 can accept 75 Ohm circuits if required.
Only plug the ADCA412 cards into the top slot associated with the RM13 rear module,
the bottom slot is not used and MUST be left vacant.
ADCA412 User Manual R2.1
22