The lower amber activity LED will display the drive activity 
of the back drive in carrier.  The actual functionality of the 
LED is set by the hard drive.  Please see your hard drive 
manual for details.

Rack Mounting Instructions

•  Elevated Operating Ambient: If installed in a closed or 

multi-unit rack assembly, the operating ambient tempera-
ture of the rack environment may be greater than room 
ambient. Therefore, consideration should be given to 
installing the equipment in an environment compatible 
with the maximum ambient temperature (Tma) specified 
by the manufacturer.

•  Reduced Air Flow: Installation of the equipment in a rack 

should be such that the amount of air flow required for 
safe operation of the equipment is not compromised.

•  Mechanical Loading: Mounting of the equipment in the 

rack should be such that a hazardous condition is not 
achieved due to uneven mechanical loading.

•  Circuit Overloading: Consideration should be given to 

the connection of the equipment to the supply circuit 
and the effect that overloading the circuits might have 
on overcurrent protection and supply wiring. Appropriate 
consideration of equipment nameplate ratings should be 
used when addressing this concern.

•  Reliable Earthing: Reliable earthing of rack-mounted 

equipment should be maintained. Particular attention 
should be given to supply connections other than direct 
connections to the branch circuit (e.g. use of power 
strips).

Limited Product Warranty

CRU-DataPort (CRU) warrants the DataPAK 1U enclosure to be 
free of significant defects in material and workmanship for a 
period of one year from the original date of purchase. CRU’s war-
ranty is nontransferable and is limited to the original purchaser.

Operation

The DataPAK 1U Multi-Lane Enclosure supports up to 4 SATA 
hard drives and uses the SFF-8470 (InfiniBand) connector. It 
requires a multi-lane cable with the SFF-8470 connector for the 
enclosure. 

NOTE: 

The DataPAK 1U Multi-Lane Enclosure does not 

include the required enclosure to host cable. 

The DataPAK 1U Multi-Lane Enclosure supports two differ-
ent multi-lane cables, the SFF-8470 (InfiniBand) to SFF-8470 
(InfiniBand) cable (CRU Part Number 7366-700-03); and the SFF-
8470 (InfiniBand) to SFF-8088 (Mini-SAS) cable (CRU part number 
7366-701-01). Consult your host bus adapter manual to determine 
which interface (connector) it supports. 

For host support CRU offers a cable assembly kit. The 4x SATA 
to SFF-8470 (InfiniBand) PCI host adapter with (4) SATA data 
cables and SFF-8470 (InfiniBand) to SFF-8470 (InfiniBand) external 
cable (CRU part number 7100-800-10) will provide the end to end 
cabling required to set up the DataPAK 1U Multi-Lane Enclosure. 

These cables are available through CRU’s authorized resellers.

Enclosure LEDs

Power LED
The green power LED will illuminate when the enclosure power 
is on.

Fan Failure LEDs
Red LEDs will flash in the event of fan failure.

Carrier LEDs

Power LED
The green power LED will light up when the carrier is properly 
installed in the chassis.

Activity LED
The upper amber activity LED will display the drive activity of the 
front drive in carrier.  The actual functionality of the LED is set by 
the hard drive.  Please see your hard drive manual for details.