background image

7

(2)

FUNC+SCAN

SC.LIST (Scan ADD or Delete).  Press FUNC+SCAN to delete current 

channel from scan list. The first digit on LCD would display. When 

Scan function is enabled, the radio would skip the deleted channel. 

Repeat this operation to Add or Delete channels from scan list. 

 

211 

+10KHZ or HI-CUT

(1)

+10KHZ  Press this key to shift frequency up by 10khz. 

When pressing this key, 10KHZ would appear on LCD and frequency 

of channels is shifted up by 10 KHZ. Repeat this operation to switch 

ON/OFF this function.

(2)

FUNC+ +10KHZ

Press FUNC+10KHZ to realize HI-CUT function. Once this function is 

enabled, the radio would cut out high frequency interference. Its use 

depends on reception conditions.
When this function is enabled, "HI-CUT" would appear on LCD. Repeat 

this operation to switch ON/OFF the function

SWR  OR  TOT

211 

(1)

SWR

When pressing this key, “SWR” icon would appear on the LCD. When 

transmitting, SRF bars indicate SWR value other than PA or PWR 

value. One bar displaying on the LCD indicates that SWR value is 

1.0. Each additional bar indicates every 0.1 added value. Repeat this 

operation to switch ON/OFF the function.

(2)

FUNC+ SWR

When pressing this key, TOT ON or TOT OFF would display on the 

LCD for 2 seconds. Repeat this operation to switch ON/OFF the 

function. When ON appears on the LCD, users can press PTT to 

transmit. Then, the radio would time the transmitting duration. Once 

the duration is beyond the set TOT time (programmable), the radio 

would emit voice prompt and stop transmitting and back to receiving 

state automatically. This function aims to protect the radio against 

power tube damage from superheating caused by long transmission.

<Rear Panel>

Accept13.8V  DC  power  cable  with  built-in  fuse  (10 Amp)  to  be 

connected.

 POWER 

231 

  EMG  OR  S/RF

221 

(1)

EMG realizes Emergency Channel Call. When emergent situation 

happens, the radio would switch to the channel set in advance to 

communicate immediately. Then the "EMG" icon would display on the 

LCD . Press EMG key again to return to previous channel.

(2)

FUNC + S/RF

S/RF is the switch of TX's or RX's S/RS indicating bar. When this 

function is enabled, "SRF"icon would display on the LCD. Repeat the 

this operation to switch ON/OFF the function.

channel. You can receive the calling, and also, can transmit on this 

channel by pressing PTT key. If there is no transmission or detected 

signal on that channel within 5 seconds(time to resume scanning can 

be programmed by PC software), radio will start scanning again. To 

exit the SCAN function, press the SCAN key or the PTT key.
The  Scan Type  above  is  the  SQ  mode  under  SCA  Selection  in 

Function Menu. If TI mode is selected and valid signal is detected, the 

radio would still start scanning when it is time to resume scanning, 

whether there is signal or not in current channel.

8

 EXT SP or PA SP

241 

EXT SP
Accept 4 to 8 ohm, 4 watt external speaker to be connected. When 

external speaker is connected to this jack, the built-in speaker is 

automatically disconnected.
PA  SP
It is used to connect a PA speaker. Before operating PA, you must 

firstly connect a PA speaker to this jack.

ATTENNA

251 

Accept 50 ohm coaxial cable with a type PL-259 plug to be connected.

CW KEY

261 

<PRESS—TO—TALK—MICROPHONE>

The receiver and transmitter are controlled by the Press-To-Talk 

switch on the microphone.
Press the switch to transmit and then release it to receive. When 

transmitting, hold the microphone two inches from the mouth and 

speak clearly in a normal “voice”. The radios come complete with low-

impedance (150 ohm) dynamic microphone.

PTT

11 

Transmitting key, Press to speak and release to receive a message.

UP/DN

21 

These key allow increasing or decreasing a channel number.

AQ

31 

(1)

When the radio is receiving a call, press this key to enable ASQ 

(Automatic Squelch Control) function. Then, "AQ" would appear on the 

LCD. Press this key repeatedly to switch on/off the function.

(2)

When the radio is receiving a call, press and hold this key for 

over 2 seconds to enable signal monitoring function. At the moment, 

whether the radio receive signal or not, the radio would detect current 

channel to check whether current channel has weak signal.Release 

AQ key to exit this function. 

(3)

Pressing PTT and AQ key at the same time, the radio would 

emit a single-tone. This tone is to help and remind two sides of 

communication to adjust frequency. The frequency of this tone is 

adjustable.

(4)

ASQ  (Automatic Squelch Control) 

ASQ  control  setting.It  has  same  function  with AQ  button  on  the 

microphone.

This jack is for Morse code operation; To operate, connect a CW 

key to this jack and place the MODE switch in the CW position (LCD 

display icon "CW")

MICROPHONE

41 

The radios come complete with low-impedance (150 ohm) dynamic 

microphone.

FUNCTION MENU SETUP

The initial functions and parameter can be changed via the following 

settings and operations. Please read the following instruction before 

making any desired amendments.

To enter Function Menu: under ON state, press and hold FUNC key for 

more than 2seconds, and then release the FUNC key to enter into the 

Function Menu Setup. Under this condition, press FUNC key to select 

different functions menu, CHANNEL SELECTOR Switches to change 

the data of Function Menu.

Summary of Contents for SS 6900

Page 1: ...10 METER RADIO USER S MANUAL Downloaded from www cbradio nl ...

Page 2: ......

Page 3: ...g DC using Keep dry Shield symbol CE conformity symbol Alert symbol indicating an incomplete harmonization of the frequency band which will result in restrictions on the use of the equipment concerned Warning SYMBOLS DESCRIPTION STORAGE TRANSPORT USING Storage Classe 1 30 85 Humidity Transport 30 85 Humidity operating temperature 30 à 50 Using cycle TX 10 RX 90 ...

Page 4: ... you through the learning process now then act as a reference in the coming years PRECAUTIONS Please observe the following precautions to prevent fire personal injury or transceiver damage Do not attempt to configure your transceiver while driving it is dangerous This transceiver is designed for a 13 8V DC power supply Don t use a 24V battery to power on the transceiver Do not place the transceive...

Page 5: ... device before starting the vehicle to avoid damage caused by spikes in the ignition When replacing the fuse you must use a fuse 10A 250V type F In no case a higher value Otherwise a fire hazard If an abnormal odor or smoke is detected coming from the transceiver turn OFF the power immediately Contact an CRT service station or your dealer Do not transmit with high output power for extended periods...

Page 6: ...edented quality your multi functional SS 6900 Radio 10 meter Radio is a new step in personal communication and is surely the best choice for professional users of CB radios Moreover with multiple connecting ports in the radio SS 6900 Radio is ready for future upgrading and functions expanding To ensure that you use the radio to the fullest please read this manual carefully before installing and us...

Page 7: ...ING 1 RESET FUNCTION Resume Factory Default 1 INSTALLATION 2 HOW TO USE YOUR CB RADIO 4 FUNCTION MENU SETUP 8 OPERATING PROCEDURE TO RECEIVE 11 OPERATING PROCEDURE TO TRANSMIT 11 SPECIFICATIONS 12 PROGRAMMING BY COMPUTER OPTION 12 RADIO ...

Page 8: ...PLIED VOLTAGE PROTACTION 241 Key Lock Function 251 WARNIGN To use the radio please connect the antenna to the location B on the back panel of the equipment firstly and then set the SWR Standing Wave Ratio before transmitting Failure to do so may result in destruction of the power amplifier which is not covered by the guarantee RESET FUNCTION Resume Factory Default This CB Radio introduces RESET FU...

Page 9: ...os the longer the antenna the better its results Your dealer will help you with your choice of antenna b Antena Movel b Mobile antenna Must be fixed to the vehicle where there is a maximum of metallic surface ground plane away from windscreen mountings There are two types of antenna Pre Regulated Antenna which should be used on a good ground plane e g car roof or lid of the boot and Adjustable Ant...

Page 10: ...elch knob to minimum e Adjust the volume to a comfortable level f Go to channel 20 D band by using either the UP or DN key on the microphone or the rotary knob Your RADIO is protected against an inversion of polarities However before switching it on you are advised to check all the connections Your equipment must be supplied with a continued current of 12 volts A Today most cars and lorries are ne...

Page 11: ...ed 4 Set CB to channel 20 D band in FM Press push to talk button on the microphone to transmit At the moment LCD would display SWR value which should be as close as possible to 1 If this is not the case re adjust your antenna to obtain a SWR value as close as possible to 1 an SWR reading between 1 and 1 8 is acceptable HOW TO USE YOUR CB RADIO 10K Appears when 10KHZ function is started EMG Appears...

Page 12: ...1 When it is receiving the LED will be green The LED will be red when it is transmitting LCD DISPLAY 141 Display frequency all kinds of information and icons FUNC 151 This is functional key Press and hold this key for 2seconds to enter into Functions Menu Setup refer to Functions Menu for more details Press FUNC key and other individual key to realize the second functions silk screened under the b...

Page 13: ... enable the DW function firstly turn the SQ control clockwise until the background noise is cut out Select the first channel to be monitored by using the CHANNEL SELECTOR knob or the channel selector keys on the microphone Press the DW key and the DW icon will flash on the LCD display Secondly follow the above procedures to select second channel to be monitored Finally press the DW key again and t...

Page 14: ...he LCD users can press PTT to transmit Then the radio would time the transmitting duration Once the duration is beyond the set TOT time programmable the radio would emit voice prompt and stop transmitting and back to receiving state automatically This function aims to protect the radio against power tube damage from superheating caused by long transmission Rear Panel Accept13 8V DC power cable wit...

Page 15: ... is receiving a call press and hold this key for over 2 seconds to enable signal monitoring function At the moment whether the radio receive signal or not the radio would detect current channel to check whether current channel has weak signal Release AQ key to exit this function 3 Pressing PTT and AQ key at the same time the radio would emit a single tone This tone is to help and remind two sides ...

Page 16: ...pear on far left of the LCD Under this condition rotate the CLARIFIER knob to change frequency of both transmitting and receiving T When this option is selected press PUSH and turn CLARIFIER knob to change transmitting frequency When pressing this key 3 icon will display on the far left of the LCD Under this condition rotate the CLARIFIER knob to change the transmitting frequency only STP When thi...

Page 17: ... the SWR Value is higher than 20 1 Default ON SWR 10 1 8 TDC Power Supplied Voltage Protection This menu is to choose whether to enable Power supplied Voltage Protection function or not ON When ON is selected the radio will detect the supplied voltage Once the voltage surpasses the voltage setup in advance the radio would display DC LO or DC HI to remind you that the voltage is not in normal state...

Page 18: ...ting Single Tone Frequency from 300HZ 3KHZ The shift step is 10HZ Default 1050HZ 14 TX MON This menu is to set Talkback Monitoring Volume for voice message sent Be sure that power supply microphone and antenna are 11 connected to the proper connectors before going to the next step Turn the radio on by tuning VOLUME control clockwise 21 Rotate the VOLUME knob to set a comfortable listening level 31...

Page 19: ...unbalanced Sensitivity SSB 0 25μV for 10dB S N N at greater than 1 2 watt of audio output AM 1 0μV for 10 dB S N N at greater than 1 2watt of audio output FM 1 0 μV for 20 dB S N N at greater than 1 2 watt of audio output Selectivity AM FM 6dB 3KHz 50dB 9KHz SSB 6 dB 2 1KHz 60dB 3 3KHz Image Rejection More than 65dB IF Frequency AM FM 10 695 MHz 1st IF 455 KHz 2nd IF SSB 10 695 MHz Adjacent Channe...

Page 20: ...he HAM version was approved in the CEPT countries and those non CEPT countries that implement the CEPT regulation TR 61 01 CEPT Countries Codes ALB AND AUT AZE BLR BEL BIH BUL HRV CYP CZE DNK EST FIN F GEO D GRC HNG ISL IRL I LVA LIE LTU LUX MKD MLT MDA MCO MNE HOL NOR POL POR ROU RUS SMR SRB SVK SVN E S SUI TUR UKR G CVA C R T FRANCE INTERNATIONAL S A R L Route de Pagny 21250 SEURRE FRANCE Capita...

Page 21: ......

Page 22: ......

Reviews: