DECLARATION  OF  CONFORMITY

European Representative’s Name and Address:

David Budge

10 Harvest Close

Yateley, GU46 6YS

United Kingdom

Equipment Type: 

Commercial Audio Power Amplifiers

Family Name: 

XTi2 Series

Model Names:

 XTi 1002, XTi 2002, XTi 4002, XTi 6002

EMC Standards:

  

EN 55103-1:2009

 EMC Compatibility – Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting 

Control Apparatus for Professional Use, Part 1: Emissions

 

EN 55103-1:2009 

Magnetic Field Emissions – Annex A @ 10cm and 1M

 

EN 61000-3-2:2006

 Limits for Harmonic Current Emissions (equipment input current less than or equal to 16A)

 

EN 61000-3-3:2008

 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply systems Rated Current less than or 

equal to 16A

 

EN 55022:2010

 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE: Radiated & Conducted, 

Class B Limits

  

EN 55103-2:2009 

EMC Compatibility – Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting 

Control Apparatus for Professional Use, Part 2: Immunity

 

EN 61000-4-2:2008 Ed 2.0

 Electrostatic Discharge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge)

 

EN 61000-4-3:2010 Ed 3.2

 Radiated, Radio-Frequency, EMC Immunity (Environment E2, Criteria A)

 

EN 61000-4-4:2007

 Electrical Fast Transient/Burst Immunity (Criteria B)

 

EN 61000-4-5:2006

 Surge Immunity (Criteria B)

 

EN 61000-4-6:2006

 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A)

 

EN 61000-4-11:2004

 Voltage Dips, Short Interruptions and Voltage Variation

Safety Standard:

 

IEC 60065: 2001Ed 7 +A1:2005

 Safety Requirements – Audio, Video, and Similar Electronic Apparatus

 

CAN/CSA 60065-03 incl. A1

 Safety Requirements – Audio, Video, and Similar Electronic Apparatus

 

UL Std No. 60065-2007

 Safety Requirements – Audio, Video, and Similar Electronic Apparatus

I certify that the product identified above conforms to the requirements of the EMC Council directive 2004/108/EC and the Low 

Voltage Directive 2006/95/EC.

Issued By:

    Harman International. 

1718 W. Mishawaka Rd. 

Elkhart, IN 46517 U.S.A.

Sue Whitfield

[email protected]

FOR COMPLIANCE 

QUESTIONS ONLY:

Date of Issue: February 1, 2012

Due to line current harmonics, we recommend that you contact your supply authority before connection.

Summary of Contents for XTi 1002

Page 1: ...of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www crownaudio com Trademark Notice Crown C...

Page 2: ...IP MENT FROM THE AC MAINS DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE AC RE CEPTACLE THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE WATCH FOR THESE SYMBOLS The lightning bolt...

Page 3: ...and Entertainment Lighting Control Apparatus for Professional Use Part 2 Immunity EN 61000 4 2 2008 Ed 2 0 Electrostatic Discharge Immunity Environment E2 Criteria B 4k V Contact 8k V Air Discharge E...

Page 4: ...nd Channel 2 using XLR connectors the amplifier inputs will automatically be summed together when selecting this preset 2 Connector the speaker as shown a If using the binding post outputs connect the...

Page 5: ...to Y mode when selecting this preset 2 Connector the speaker as shown a Connect the speaker you wish to receive the low and mid frequencies 1 2kHz and below to Channel 1 output using Speakon Banana Pl...

Page 6: ...when selecting this preset 2 Connector the speaker as shown a If using the binding post outputs connect the positive terminal of the speaker to the positive terminal of Channel 1 and the negative ter...

Page 7: ...n Banana Plugs or bare wire Follow these quick steps to configure the amplifier for SUBSYNTH operation 1 Push the Set Enter button and you will see the word Preset flashing 2 Push the Set Enter button...

Page 8: ...hannel illuminate when the amplifier is ready to produce audio Signal Presence Indicator Two green LEDs one for each channel illuminate when the channel input exceeds 40dBu Useful for troubleshooting...

Page 9: ...nd Band Manager software Binding Post Output Jacks One pair per channel accepts banana plugs or bare wire Note Binding Post outputs on European models come with safety plugs installed to prevent Europ...

Page 10: ...preset When you are modifying a preset its icon flashes You can scroll through its settings with the Prev and Next buttons When you see the desired setting select it by pressing Sel Doing nothing ret...

Page 11: ...The Subharmonic Synth feature takes the low frequencies and synthesizes or creates new frequencies that are one octave lower The two signals are then summed together Also new are two user adjustable...

Page 12: ...cations Early mode turns the fan on sooner at a lower temperature and Full speed mode turns the fan on full speed full time Full speed mode is not recommended for dirty environments Advanced Monitorin...

Page 13: ...ncy Response at 1 watt into 4 ohms 20 Hz to 20 kHz 0 dB 1 dB Signal to Noise Ratio below rated 1 kHz power at 8 ohms A weighted 100 dB 103 dB in XTi 6000 Damping Factor 8 ohm 10 Hz to 400 Hz 500 Cross...

Page 14: ...able 10 100V 120V 220 240V 50 60 Hz Operating Temperature 0 C to 40 C at 95 relative humidity non condensing Construction Ventilation Flow through ventilation from front to back Cooling Heat sinks and...