Integrated Processing Features

Delay

There is up to 50msec of delay available in the signal processing for time aligning your speakers. The software 

allows you to enter the amount of delay needed in the form of seconds, feet, or meters and does the calculation 

for you.

PeakX Plus Limiter:

Feed-forward output limiter with user-adjustable attack, release and threshold (0.1 dB resolution), plus 
integrated feedback limiter to minimize amplifier clipping.

Advanced Thermal Control

In this section, you can tailor the fan speed to specific applications. You have the choice of the following modes:

•  Normal

•  Early

•  Full-Speed

The fan mode can be changed using the front panel buttons at start-up or in the software. The default mode is 

normal and should work fine for most applications. Early mode turns the fan on sooner at a “lower” temperature, 

and Full-speed mode turns the fan on full-speed full-time. Full-speed mode is not recommended for “dirty” 

environments.

Advanced Monitoring

This feature allows you to have software visibility of both the Power Supply Temperature and AC Line voltage. 

AC Line voltage is “derived” from the amplifier rail voltage and is an approximation of the AC line voltage. This 

allows you to monitor the health of your amplifiers and provides for troubleshooting.

Front Panel Lock-Out

To disable or lock the buttons from the front panel, hold the Prev and Next at the same time until the screen says 

“locked”. The rotary knobs (attenuators) will still operate. To unlock, hold Prev and Next until the screen says 

“unlocked”.

The front panel can also be locked out from the software as well from the main panel.  However once it is locked 

in the software, it can only be unlocked from the software. You cannot unlock from the front panel. 

The rotary 

knobs (attenuators) will still operate.

Summary of Contents for XTi 1002

Page 1: ...of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www crownaudio com Trademark Notice Crown C...

Page 2: ...IP MENT FROM THE AC MAINS DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE AC RE CEPTACLE THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE WATCH FOR THESE SYMBOLS The lightning bolt...

Page 3: ...and Entertainment Lighting Control Apparatus for Professional Use Part 2 Immunity EN 61000 4 2 2008 Ed 2 0 Electrostatic Discharge Immunity Environment E2 Criteria B 4k V Contact 8k V Air Discharge E...

Page 4: ...nd Channel 2 using XLR connectors the amplifier inputs will automatically be summed together when selecting this preset 2 Connector the speaker as shown a If using the binding post outputs connect the...

Page 5: ...to Y mode when selecting this preset 2 Connector the speaker as shown a Connect the speaker you wish to receive the low and mid frequencies 1 2kHz and below to Channel 1 output using Speakon Banana Pl...

Page 6: ...when selecting this preset 2 Connector the speaker as shown a If using the binding post outputs connect the positive terminal of the speaker to the positive terminal of Channel 1 and the negative ter...

Page 7: ...n Banana Plugs or bare wire Follow these quick steps to configure the amplifier for SUBSYNTH operation 1 Push the Set Enter button and you will see the word Preset flashing 2 Push the Set Enter button...

Page 8: ...hannel illuminate when the amplifier is ready to produce audio Signal Presence Indicator Two green LEDs one for each channel illuminate when the channel input exceeds 40dBu Useful for troubleshooting...

Page 9: ...nd Band Manager software Binding Post Output Jacks One pair per channel accepts banana plugs or bare wire Note Binding Post outputs on European models come with safety plugs installed to prevent Europ...

Page 10: ...preset When you are modifying a preset its icon flashes You can scroll through its settings with the Prev and Next buttons When you see the desired setting select it by pressing Sel Doing nothing ret...

Page 11: ...The Subharmonic Synth feature takes the low frequencies and synthesizes or creates new frequencies that are one octave lower The two signals are then summed together Also new are two user adjustable...

Page 12: ...cations Early mode turns the fan on sooner at a lower temperature and Full speed mode turns the fan on full speed full time Full speed mode is not recommended for dirty environments Advanced Monitorin...

Page 13: ...ncy Response at 1 watt into 4 ohms 20 Hz to 20 kHz 0 dB 1 dB Signal to Noise Ratio below rated 1 kHz power at 8 ohms A weighted 100 dB 103 dB in XTi 6000 Damping Factor 8 ohm 10 Hz to 400 Hz 500 Cross...

Page 14: ...able 10 100V 120V 220 240V 50 60 Hz Operating Temperature 0 C to 40 C at 95 relative humidity non condensing Construction Ventilation Flow through ventilation from front to back Cooling Heat sinks and...

Page 15: ...n a reasonable time after receipt of the defective product at our authorized service center or our factory All expenses in remedying the defect including surface shipping costs in the United States wi...

Page 16: ......

Reviews: