NAME
Access
(R/W)
Possible value on the serial port
of the unit
Comments
SYS.LCDMENUS
R/W
"NORMAL" or "ADVANCED"
Sets the display type on the front panel
screen
SYS.LOCALCOM.ECHO R/W
"ON"
or
"OFF"
Adds the local echo on the front panel serial
port
SYS.LOCALCOM.SPEED R/W 9600,19200,38400,57600,115200 Speed of the front panel serial port
SYS.LOG R
List of the latest 200 events (configuration
changes, alarm start date and end date…)
SYS.LOG.CLR
W
Clears the event list
SYS.NAME R/W
XXXX
X=[A…Z]
Equipment
name
SYS.OPT.LIST
R
RF,RC,AIP,TUN,IP,COM,REC
List of implemented options
SYS.PASSWORD
R/W
xxx x=[A..Z;0..9]
Password for the console and front panel
display. ‘NONE’ disables the password
SYS.PASSWORD.RESET
R/W
xxx x=[A..Z;0..9]
Creates a text string to unlock the password
if it has been forgotten
SYS.PCAP R
[0..999]
Nominal power of the unit: example
"300"=>300 W
SYS.RAZ
W
"RAZ"
Reloads NVRAM default values
SYS.RST
W
Reset of all parameters.
SYS.RST.CPU W "RST"
General reset of the µc. Sends the return
code: RST
SYS.SN R
YYMMXXXX
A,M,X=[0..9]
Serial number of the unit: Y => year, M =>
month, X => number
SYS.SOFTREL
R
xx.xx.xx x=[0..9]
Software version: example "3.0.1"
SYS.SOFTREL.LIST
R
xx.xx.xx x=[0..9]
List of the exciter software versions
CPU;DSP;FPGA;IP;EXC;A/IP;TUN
SYS.TIME
R/W
HH:MM:SS
Reads and sets the amplifier time
SYS.TYPE
R
xxx x=[A..Z;0..9]
Unit type: example "E35" for E Series 350 W
SYS.UPTIME R
[0..99999999]
Indicates the number of working hours since
commissioning
6.2.2. Measurement
commands
NAME
Access
(R/W)
Possible value on the serial
port of the unit
Comments
MEAS.12V
R
xx.x x=[0..9]
Measures the 12 V voltage
MEAS.5V
R
xx.x x=[0..9]
Measures the 5 V voltage
MEAS.AMB R
±[0..125]
Measures the ambient temperature from 0
to 125°C. "52"=>52°C.
MEAS.DEV.PEAK R -150,0…150,0
Gives the peak value for the signal deviation
in kHz
MEAS.DEV.RMS R
-150.0…150.0
Gives the average value for the signal
deviation in kHz
MEAS.N12V
R
-xx.x x=[0..9]
Measures the -12 V voltage
MEAS.PFWD R
[0..9999]
Measure of forward power. examples: "20"
or "300" => 300 W
MEAS.PREF
R
xxx.x x=[0..9]
Measure of reflected power: "20" => 2 W
MEAS.VSWR
R
XX.X X=[0..9]
VSWR measure "01.0" or "20.0"
MEAS.VSWRTRIP
[0..99]
Gives the number of reflected power safety
in the past hour