Neutral (Blue) « N » &
Phase (Brown) « L »
connects to power
Alimentation
Neutral(Blue) « N » &
Phase (Brown) « L »
From the filter area
Earth/Ground(Yellow/
Green)
C.3. Changing the surge protector
To check whether the surge protector is damaged, remove the top cover. If the surge protector indicator
LED is on, it is ok. If the LED is off, the surge protector needs to be replaced.
The surge protector is located between the power supply bloc and the mains filter.
Crown Broadcast FME 350 W / 750 W / 1000 W:
1. Disconnect the unit.
2. Unscrew the top cover and remove it.
3. Using pliers, remove the metal washers that keep the surge
protector in place on the rivets and unscrew the cables
connecting it to the power bloc, to the mains filter and to the
ground.
1. Replace the old surge protector with the new one.
2. Connect the 5 wires of the terminal as shown.
3. Snap the washers on the rivets to secure the
surge protector in the chassis.
4. Set the cover back in place.