background image

INSTALLATION & OPERATION MANUAL 10058 REV 5 (09/21)

 PAGE

2    

OF 20

Electric Cabinet Base Convection Steamer

SAFETY PRECAUTIONS

Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of 

precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, 

service personnel, or to the equipment.

 

CAUTION

 

WARNING

NOTICE

This symbol warns of immediate hazards that will result in severe injury or death.

This symbol refers to a potential hazard or unsafe practice that could result in injury or death.

This symbol refers to a potential hazard or unsafe practice that could result in injury, product 

damage, or property damage.

This symbol refers to information that needs special attention or must be fully 

understood, even though not dangerous.

 

DANGER

 

 

WARNING

Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read 

the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.

 

CAUTION

Operating, testing, and servicing should only be performed by qualified personnel.

Copyright © 2021 by Crown. All rights reserved. Published in the United States of America.

Safety Precautions

IMPORTANT NOTES FOR INSTALLATION AND OPERATION

 

 

WARNING

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages 

that follow this symbol to avoid possible injury or death.

 

 

WARNING

FOR YOUR SAFETY: 

 

Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

NOTICE

This manual should be retained for future reference.

It is recommended that this manual be read thoroughly and that all instructions be followed carefully.

 

NOTICE

This product is intended for commercial use only. NOT FOR HOUSEHOLD USE.

 

NOTICE

Contact the factory, the factory representative or local service company to perform maintenance and repairs.

Summary of Contents for ECX-10

Page 1: ...______________ WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroug...

Page 2: ...oper installation operation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before instal...

Page 3: ...tion Steamer RETAIN THIS MANUAL FOR FUTURE REFERENCE Table of Contents Important Notes For Installation and Operation 2 Service Connections 4 Introduction 5 Installation 5 Operation 7 Periodic Mainten...

Page 4: ...d on data plate BOILER FEED WATER 1 2 13 mm NPT at 25 50 PSI 170 345 kPa CONDENSATE COLD WATER 1 2 13 mm NPT at 25 50 PSI 170 345 kPa OPTIONAL STEAM TAKE OFF CONNECTION 3 4 19 mm IPS optional to opera...

Page 5: ...floor through the anchoring holes provided in the rear flanged adjustable feet 4 Remove appliance from installation position and drill holes in locations marked on the floor See installation diagram o...

Page 6: ...lectrical power supply and place a tag on the disconnect switch to indicate that you are working on the circuit IMPORTANT Use copper wire suitable for at least 200 degrees Fahrenheit 90 degrees Celsiu...

Page 7: ...hen enough water has entered the boiler the red Low Water pilot will come on for approximately 10 seconds and then the amber Standby pilot light will come 4 Press the Reset switch to begin boiler oper...

Page 8: ...is installed on the boiler Should the pressure exceed the limit of this device the boiler will be shut down and switch to a state of lockout The Pressure pilot light red and the Standby pilot amber w...

Page 9: ...t indicates the end of the cooking cycle and that no more steam is entering the compartment Cooking pilot light will go off and ready pilot light will come on Buzzer must be shut off by turning the ti...

Page 10: ...ulates into the float chamber sand scale and other sediment may be deposited in the float chamber While the chamber has been designed with a large accumulation bowl it is necessary to flush the sedime...

Page 11: ...n its original position 4 Wash gasket sealing surface with mild detergent to remove harmful food acids and rinse 5 Water level control should be opened daily to blow down sediment and scalant 6 Observ...

Page 12: ...r 3 Insert appropriate hose or tube through fitting and pour in half gallon US of CLR Descaling Solution or use the Optional Deliming Assembly DPA 1 available from your dealer 4 Replace 3 4 pipe plug...

Page 13: ...ure to build until unit shuts off This should occur at 15 psi Set the high signal to switch at 14 5 psi on the gauge and the low signal to 13 0 psi 2 OVERRIDE PRESSURE SWITCHES Allow pressure to incre...

Page 14: ...3 Water level control clogged or defective unable to operate fill valve 4 Check drain valve is closed Also check that water level control valve is closed 5 Supply water pressure too low Automatic Blow...

Page 15: ...lb Can 10 lb Can Canned Vegetables 6 10 Lb Can Prunes Dried 12 to 15 Cooking Chart COOKING CHART The following table lists suggested cooking times and weights These times which will vary depending on...

Page 16: ...8 6 6 4 lb 5 lb 5 lb Cabbage Fresh 1 6 Cut 8 5 lb Carrots Baby Whole Frozen Crinkle Cut Frozen Sliced Fresh 8 7 8 11 7 lb 4 lb 9 lb Cauliflower Flowerettes Frozen Fresh 6 7 8 4 lb 5 lb Celery 1 Diagon...

Page 17: ...to protrude above pans since this will interfere with steam circulation between pans in the compartment Always preheat compartments for satisfactory results When time does not allow for defrosting of...

Page 18: ...INSTALLATION OPERATION MANUAL 10058 REV 5 09 21 PAGE 18 OF 20 Electric Cabinet Base Convection Steamer Notes...

Page 19: ...INSTALLATION OPERATION MANUAL 10058 REV 5 09 21 PAGE 19 OF 20 Electric Cabinet Base Convection Steamer Notes...

Page 20: ...ize however that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Crown Authorized Service Agency or...