4 Specifications

Note: The following specifications apply to all units in dual
mode with both channels driven into 8 ohm loads and an
input sensitivity of 26 dB gain unless otherwise specified.

Standard 1 kHz Power: 

This term refers to maximum aver-

age power in watts at 1 kHz with 0.1% THD.

Full Bandwidth FTC Power: 

This term refers to standard

FTC power in watts from 20 Hz to 20 kHz with 0.1% THD.

120 VAC, 60 Hz Units:

 These North American units have

dedicated transformers for 120 VAC, 60 Hz power mains.

International Units:

 These units have a convertible trans-

former for 100, 120, 200, 220 and 240 VAC, 50 to 400 Hz
power mains.

Performance

Frequency Response:

 ±0.1 dB from 20 Hz to 20 kHz

at 1 watt.

Phase Response:

 +10 to –15 degrees from 20 Hz to

20 kHz at 1 watt.

Signal-to-Noise:

 106 dB from 20 Hz to 20 kHz at full

bandwidth FTC power.

Total Harmonic Distortion (THD):

 Less than 0.001%

at full bandwidth FTC power from 20 Hz to 400 Hz in-
creasing linearly to 0.05% at 20 kHz.

Intermodulation Distortion (IMD):

 (60 Hz and 7 kHz

4:1) Less than 0.01% from 0.25 watts to full bandwidth
FTC power, and less than 0.05% from 0.01 to 0.25 watts.

Crosstalk:

 Greater than 100 dB below full bandwidth

FTC power from 100 Hz to 1 kHz decreasing linearly to
80 dB at 20 kHz.

Damping Factor:

 Greater than 400 from DC to 400 Hz.

Controlled Slew Rate:

 6 volts per ms. (Slew rates are

limited to useful levels for ultrasonic/RF protection.)

Voltage Gain:

 (At the maximum level setting) 20.6:1

±3% or 26.3 dB ±0.3 dB. Refer to Appendix A for infor-
mation on the 0.775 volt sensitivity setting.

Power

Output Power:

Note: Maximum average power per channel at 1 kHz
with 0.1% or less THD.

D-45:

Dual mode (both channels driven):

35 watts into 4 ohms.
25 watts into 8 ohms.
20 watts into 16 ohms.

Bridge-Mono mode:

70 watts into 8 ohms.
50 watts into 16 ohms.

D-75A:

Dual mode (both channels driven):

55 watts into 4 ohms.
40 watts into 8 ohms.
25 watts into 16 ohms.

Bridge-Mono mode:

110 watts into 8 ohms.

80 watts into 16 ohms.

Load Impedance:

 Safe with all types of loads. Rated

for 4 to 16 ohms in dual mode, and 8 to 16 ohms in
bridge-mono mode.

Required AC Mains:

 100, 120, 200, 220 and 240 VAC

(±10%), 50 to 400 Hz for international units (depend-
ing on the transformer configuration). North American
120 VAC, 60 Hz units are not convertible and can only
be used at the specified voltage and frequency. All
units draw 15 watts or less when idle. Maximum AC
power consumption is 150 watts.

Controls

Power:

 A two-position front panel rotary on/off switch.

Level:

 An independent 31-position detented front

panel level control for each channel.

Dual/Mono:

 The dual/mono jumper is located inside

the amplifier (refer to Appendix A).

Ground Lift:

 To prevent ground loops, the chassis and

signal grounds are separated (or “lifted”) by a perma-
nent impedance installed between them. There is no
control for this feature.

Indicators

Signal Presence:

 The green front panel indicator for

each channel flashes synchronously with the channel’s
output signal to indicate its presence.

Input/Output Comparator:

 The red Input/Output

Comparator (

IOC) indicator for each channel flashes if

any type of distortion reaches 0.05%.

Input/Output

Input Connector:

     A balanced 3-pin female Neutrik

®

combination XLR and ¼-inch phone connector for
each channel.

Input Impedance:

 Nominally 20 K ohms, balanced.

Nominally 10 K ohms, unbalanced.

Summary of Contents for D-45

Page 1: ...0 0 10 20 1996 by Crown International Inc P O Box 1000 Elkhart Indiana 46515 1000 U S A Telephone 219 294 8000 D Series amplifiers are produced by the Professional Audio Division of Crown Internationa...

Page 2: ...A warrants to you the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER of each NEW Crown prod uct for a period of three 3 years from the date of purchase by the original purchaser the warranty period that...

Page 3: ...G TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE Magnetic Field CAUTION Donotlocatesensitivehigh gainequip ment such as preamplifiers or tape decks directly abov...

Page 4: ...Page 4 D 45 D 75A Power Amplifiers...

Page 5: ...er s performance Crown further protects your investment with the industry s only three year No Fault full warranty After learning about your amplifier s fea tures facilities and capabilities you ll un...

Page 6: ...al and bridge mono modes have important wiring differences so be sure to note the requirements for the mode you select D U A L Dual mode installation is very intuitive The channel 1 input feeds the ch...

Page 7: ...hannel 1 input feeds both outputs and the channel 2 output is inverted To use bridge mono mode without bridging the outputs wire your loudspeakers as you would for dual mode but invert the polarity of...

Page 8: ...nductors together when making or breaking connections for example a stan dard three wire stereo phone plug 3 Never use connectors that can be plugged into an AC power receptacle 4 Avoid connectors wit...

Page 9: ...other loads of less than 3 ohms install an isolating ca pacitor in series with the positive output Such operation may damage the load and needlessly activate the amplifier s V I limiting 7 Operate th...

Page 10: ...ms or higher should not activate the protection system All voltage amplification circuitry is designed to limit current So in the extremely unlikely event of a device failure the amplifier will preven...

Page 11: ...setting Power Output Power Note Maximum average power per channel at 1 kHz with 0 1 or less THD D 45 Dual mode both channels driven 35 watts into 4 ohms 25 watts into 8 ohms 20 watts into 16 ohms Bri...

Page 12: ...rotection for short cir cuits open circuits and mismatched loads Turn On Minimum thumps Power up is instantaneous with no program delay Construction Durable black finish on aluminum front panel with g...

Page 13: ...Bridge Mono balanced output FTC Continuous Average Power at 0 1 THD See note 1 20Hz 20kHz 1 kHz Single Cycle Tone Burst Watts at 0 05 THD See note 3 40 mS Tone Burst Watts at 0 05 THD See note 4 1 kH...

Page 14: ...cal Support Group 5 2 2 Factory Service To obtain factory service fill out the service informa tion page that follows and send it along with your proof of purchase and the defective unit to the Crown...

Page 15: ..._________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ________...

Page 16: ...Page 16 D 45 D 75A Power Amplifiers...

Page 17: ...sis CAUTION Only a qualified technician should at tempt to change the amplifier s internal settings A 1 1 Opening the Amplifier Chassis Before undertaking this procedure please read Ap pendix A 1 2 an...

Page 18: ...r amplifier has excellent cross talk characteristics so each channel can be used as an independent single channel amplifier For common stereo applications left and right source signals can be connecte...

Reviews: