DriveCore Install Network Display Series
Power Amplifiers
page 7
Operation Manual
Fault
Signal
Indicators:
Signal Indicators (green): LEDs indicate signal presence
Ready Indicator (blue): When this indicator is activated, the amplifier is
ready to pass audio.
Fault Indicator (red): Flashes when the amplifier output channel has stopped operating
Cooling Vent Grille
Filtered venting for cooling
circulation. Do not block or
cover these vents.
Front Panel Contro
l
Allows user to edit and select
amplifier controls in the LCD
Screen.
Power Button
Power Ring Indicator (Green) - Illuminates
when the amplifier is plugged into a wall
outlet with acceptable power. NOTE: Power
Button is disabled when AUX port Sleep
circuit is used.
Power Indicator (blue)
Illuminates when the amplifier is ON and
acceptable AC line voltage is present.
Blinks when AC line voltage is outside ±10%
range.
Flashes for 4 seconds if Power button pressed
when amplifier is in sleep mode.
Note: Four channel model shown. Indications per channel pair are identical for 4 and 8 channel models.
Data Indicator (yellow)
Illuminates when data present on the data
network only. AVB connectivity
is not a part of this indicator.
LCD Screen
Shows enabled presets and
DSP functions in addition
to level clip and thermal
information.
Next-Prev-Menu/Exit
Buttons
Allows access to menu items
from the front panel.
Cooling Fan Outlet
Outlets for cooling air flow.
Do not block or cover these
outlets.
Auxiliary Connector
3-pin plug-in type connector,
Enables SLEEP mode and
monitoring of AMP STATUS unless
the amplifier is in any of these
conditions: OFF, SLEEP, or FAULT.
(see Page 31)
Output Connectors
One four-pole touch-proof
terminal strip per channel pair.
Accepts up to 10 AWG wire or
terminal forks.
AVB Digital Audio
Transport
Primary and Secondary AVB port
for fault tolerance with control
through a separate Ethernet port.
Ethernet
For monitoring and control of the
amplifier over Category 5e wiring
through the Audio Architect
software.
GPIO
GPIO General Purpose
Input/Output port for
additional control and
monitoring of the amplifier.
Power Breaker
Resettable breaker to prevent
the amplifier from excessive
current draw.
Input Connectors
One 6-pin plug-in connector
per input pair. High impedance
balanced. (Refer to Page 8).
AC Power Inlet
Standard 20A IEC inlet
for detachable connector
Universal Power Supply
100 - 240V, 50/60Hz
Front Panel Features
Back Panel Features