3.0 OPERATION INSTRUCTIONS
WARNING: In the event of main burner ignition failure, a 5 minute
purge period must be observed prior to re-establishing ignition
source.
WARNING: In the event you smell gas, shut down equipment at the
main shut off valve and contact the local gas company or gas
supplier for service.
CAUTION: The appliance and its parts are hot. Use care when
operating, cleaning and servicing the appliance.
1.
Open manual gas shut off valve located on back of right-hand console facing front of unit.
2.
Ensure skillet pan is in the down position.
3.
Turn power switch ON. Set thermostat dial to desired setting. RED pilot light will come
ON.
4.
This will turn on electronic ignition. When the glow coil has reached temperature, the gas
solenoid valve will open supplying gas to the burner. GREEN pilot light will come ON.
5.
Gas in burner is ignited by the glow coil.
6.
When ignition is complete, the flame sensor signals the controller to shut off the glow coil.
7.
When the skillet has reached set temperature, the pilot lights will go off and the burner will
shut off. The unit will cycle “ON” and “OFF” to maintain set temperature.
8.
Turn power “OFF” and thermostat “OFF” when skillet not in use.
NOTICE: If gas supply is interrupted during operation, a five minute
period of complete shut off of gas supply is required before