37
37
Circulator
start?
120 volts at
C1
&
C2
?
N
Remove t'stat or
zone valve end
switch wires from
T
&
TV
terminals on
L8124E. Install
temporary jumper
across terminals
T
and
TV
.
Does
circulator
run now?
*
Defective
L8124E-see
Note 6 on page
33.
* Boiler water
temperature
has dropped
below low limit
setting
*
Loose connection in t'stat or
zone valve end switch wiring
*
Defective t'stat or zone
component
*
T'stat or zone system
miswired-consult t'stat or
zone valve manufacturer's
instructions
N
Do burner and
circulator shut
down at end of
call for heat?
END
Pull wire off of
T
terminal on
aquastat. Does
boiler shut down?
*
T'stat or
zone valve
wiring calling
for heat
*
T'stat wires
shorted
* Boiler water
temperature
has dropped
below low limit
setting
*
Internal boiler
wiring
problem,
consult Crown
representative
*
Defective
L8124E
*
Sensing bulb not
bottomed out in
well
*
Seized or
defective
circulator
*
Bad electrical
connection
between
C1
or
C2
and
circulator
Y
N
Y
N
Y
N
Y
Y
Y
N
N
Y
Y
N
Main
burners
light?
*Boiler water
temperature
exceeds high limit
setting
* Defective
L8124E
Y
N
24 volts
across
T
&
TV
?
120 volts
across
terminals at
circulator?
Do burners
shut down before
gage temp
exceeds high limit
s15F?
Summary of Contents for CWI103
Page 2: ......
Page 17: ...15 15 FIGURE 12 INDIRECT WATER HEATER BOILER SIDE PIPING FIGURE 11 STANDARD BOILER PIPING ...
Page 34: ...32 32 Notes ...
Page 41: ...39 39 Notes ...
Page 43: ...41 41 ...
Page 45: ...43 43 ...
Page 47: ...45 45 ...
Page 49: ...47 47 FIGURE A1 BASE HEAT EXCHANGER FLUE COLLECTOR ASSEMBLY ...
Page 51: ...49 49 FIGURE A2 JACKET INSTALLATION ...
Page 53: ...51 51 FIGURE A3 TAPPING LOCATIONS SEE TEXT FOR TAPPING USES ...
Page 54: ...52 52 Notes ...
Page 55: ...53 53 Notes ...