SETTING UP THE DETECTOR
PET IMMUNITYJUMPER SETTING
The PET jumper on the left side is used for setting the
PET Immune function - up to 12kg or 25kg, depending
on the pet size.
LED ENABLE JUMPER SETTING
The LED jumper on the right side is used for setting -
LED Enable / Disable.
OFF -
The LED is disabled.
ON -
LED ENABLE. The LED will activate when the
detector is in alarm condition.
** Factory Setting
PULSE WIDTH JUMPER SETTING
The PULSE jumper is used for setting the PULSE
count function in order to provide PIR sensitivity control
according to the environment.
TESTING THE DETECTOR
Upon installation, the unit should be thoroughly tested to
verify proper operation. The end user should be
instructed on how to perform a walk test weekly.
Walk test (in local mode LED jumper = ON)
1. Remove front cover.
2. Set LED Jumper to ON position.
3. Reassemble the front cover.
4. Start walking slowly across the detection zone.
5. Observe that the LED lights whenever motion is
detected.
6. Allow 5 sec. between each test for the detector to
stabilize.
7. After the walk test is completed, you can set the
LED jumper to AUTO position.
Note:
To assure proper operation, the range and coverage
area should be checked at least twice a year.
For UL installations the detector shall be tested
annually.
Note:
The LED Switch does not affect the operation of the relay.
When an intrusion is detected, the LED will activate
according to LED jumper position and the ALARM relay will
switch into alarm condition for 2 sec.
TECHNICAL SPECIFICATION
Detection Method
Quad (Four element)
PIR & microwave pulse Doppler
Detection Range
2 ~ 15m @ H=1.8 ~ 2.4m
Power Input
9.6 to 16
Vdc
Current Draw
Active:
18mA
(± 5%)
Standby:
21mA
(± 5%)
Temp Consumption
Yes
Alarm Period
2 ± 1 sec
Alarm Outputs
Form C - NC&NO
28Vdc 0.1 A with 10 Ohm
series protection resistors
Tamper Switch
N.C 28Vdc 0.1 A with 10 Ohm
series protection resistors
open when cover is removed
Warm up Period
45 sec
Operation Temp
-10ºC ~ +50 ºC (14 ºF~122 ºF)
Dimensions
116 mm x 59mm x 37mm
Weight
75gr.
STANDARDS
European Council Directive 2004/108/EC
EN50130-4+A1+A2
EN61000-6-3
EN55022
EN50371
EN50130-5
EN50131-1
EN50131-2-2
SAFETY LVD 2006/95/EC
EN60950-1 (93/68/EEC)
Security Grade 2, Environmental Class II
For more detailed instruction please refer the manuals
which you could download from the internet at:
www.thecrowgroup.com
Certified by: ANPI
INCERT NUMBER
XXXXXX
Option B - Connecting single detector with 2 wire and EOL resistors
EOL Connection Options
The End-Of-Line connection options are described in the
following drawings.
Set
J3 JUMPER “2/4”
according to connection option
Set
J4 “REOL” and J2 “RAL” Jumpers
according to
EOL resistors value (see fig. 3)
Option A - 4 Wire Connection with EOL
Option C - Connecting multiple detectors with 2 wire and EOL resistors
CROW ELECTRONIC ENGINEERING LTD. ("Crow") - WARRANTY POLICY CERTIFICATE
This Warranty Certificate is given in favor of the purchaser (hereunder the "
Purchaser
") purchasing the products directly from Crow or from its authorized distributor.
Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the last day of the week and
year whose numbers are printed on the printed circuit board inside these products (hereunder the "
Warranty Period
").
Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its sole discretion and subject to Crow's procedures, as such procedures
are form time to time, to repair or replace, free of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal use and service.
Repaired products shall be warranted for the remainder of the original Warranty Period.
All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to Crow for repair or replacement shall be borne solely by the
Purchaser.
Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become defective) due to: (a) alteration of the products (or any part thereof) by
anyone other than Crow; (b) accident, abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d) failure caused by software or
hardware which Crow did not provide; (e) use or storage other than in accordance with Crow’s specified operating and storage instructions.
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular purpose or otherwise, which extend beyond the description on the face
hereof.
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole and exclusive liability toward the Purchaser in connection with the
products, including without limitation - for defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities, whether oral, written, (non-
mandatory) statutory, contractual, in tort or otherwise.
In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of profit, and whether occasioned by negligence of the Crow or any third
party on its behalf) for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not represent that these products
can not be compromised or circumvented; that these products will prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that these
products will in all cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary, fire, robbery or other events occurring without providing
an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result.
Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on claim that these products failed to give any warning.
If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products, regardless of cause or origin, Crow’s maximum liability shall not in any
case exceed the purchase price of these products, which shall be the complete and exclusive remedy against Crow.
These instructions supersede all previous issues in circulation prior to October 2010.
CROW ELECTRONIC ENGINEERING LTD.
ISRAEL
:
Crow Electronic Engineering Ltd.
12 Kineret St. Airport City
P.O. Box 293
Ben Gurion Airport , 70100
Tel: 972-3-9726000
Fax: 972-3-9726001
www.thecrowgroup.com
[email protected]
[email protected]
P/N 7101055 REV. A Y.S
- 2 -
NO:
Pet Immune non-active -
Suppresses alarm for pets up
to a weight of 12 kg.
** Factory Setting
YES:
Pet Immune active - Suppresses
alarm for pets up to a weight of 25 kg
N345
Very stable environment
Jumper #1 = ON
Without PET
Moderate nuisance
situation,
Harsh environment