4
Learning Mode
Learning the FW2-KP in the Runner2
Notes:
The learning process between the Runner2 with the FW2-KP should be performing before
the installation of the FW2-KP.
Wired keypad is required to perform the learning process of the FW2-KP.
After Power the FW2-KP with battery, display will present “Keypad isn't learned press '
P+ENTER”.
Command or Instruction
Description
1
Enter into Installer mode
P >>Installer Code>>E
Wired Keypad
2
Learn the FW2-KP as a pendent
P>>18>>E
(e.g. P18E95E)
3
Choose User Number
80-100>>E>>E
Learning process start ( followed beeps)
4
Press the buttons P + ENTER
simultaneously on the FW2-KP
The FW2-KP should be learned ( message on
wired LCD keypad " found # "
#= User number
5
Set the User Type to Pendent
P>>2>>E>>USER No>>1>>E
6
Set the User Access
P>>4>>E >>USER No>> E
Deactivate options 1,3 and 4
Function Testing after learning.
After the learning completed and before the installation verify that the FW2-KP is
functioning.