2/3
MOUNTING REQUIREMENTS
Incrementation of value T by pressing one of the 4 keys
13
corresponding to each digit.
NOTE:
a) During operation of the timer, change of time delay values:
•
taken into account immediately if your display is on the up count (Up) and if the new
value is greater than the time that has already elapsed,
•
will be taken into account in the next cycle if you are on a down count display (down).
b) The unit is supplied with the fol/owing configuration: 0.100 s, d (down), C (mode).
c) If, inadvertently, you enter the unit test procedure with the entire screen or certain
segments of the screen flashing, press the Mode pushbutton until Bp is obtained on the
screen, then press Valid to return to normal operation.
UTILIZATION PRECAUTIONS
-
The power cables and input circuits must be separate
-
A minimum requirement for ventilation and protection from vibration must be proven.
-
This equipment contains a lithium battery, do no incinerate the unit.
Configuration mode
= Press one of
the 4 keys
Time Display
Sec., Min., Hr., Hr : Min,
Hr : Min : Sec
U d
U = Up Count
d = Down Count
RUN MODE
T RANGE
UP DOWN