UNITED KINGDOM
•
CUSTOMER SERVICE
tel
020 8247 9300
internet
www.clasohlson.co.uk
postal
10 – 13 Market Place, Kingston upon Thames, Surrey, KT1 1JZ
Ver
. 20180919
Digital time switch
Art.no 18-2029
Modell EMT757-UK
18-2175
EMT757-UK
36-2901
EMT757
36-4600
EMT757
36-5035
EMT757x2
Please read the entire instruction manual before using the product and save it for
future reference. We apologise for any text or photographic errors and any changes
in technical data. If you have any questions concerning technical problems please
contact our Customer Service Department.
Product Description
Digital time switch with 20 on/off activations per day.
• CD
• Random function (random on and off activation)
• LCD-display
• Safety shuttered socket
Buttons and Functions
Set time
Note:
The time switch must be in normal mode (time) before setting of time and week
day. Push
CLOCK
to return to normal mode.
1. Push and hold
SET
until the week indicator blinks.
2. Push
▲
+
to change week day forward, or
▼
−
to change week day backwards.
The selected week day is shown in the display.
3. Push
SET
to confirm. The hour setting blinks in the display.
4. Use
▲
+
and
▼
−
to set hours.
5. Push
SET
to confirm. The minute setting blinks in the display.
6. Use
▲
+
and
▼
−
to set minutes.
7. Push
CLOCK
to return to normal mode.
Summer/Winter time
Press
CLOCK
and
▼
−
at the same time to switch between summer and winter time.
“S” is shown on the display to indicate summer time.
Installation of programme
1. Push
ON/OFF
to set the time switch in AUTO mode.
2. When the display is in normal mode, press
▲
+
to return to settings mode. “1ON”
is shown on the display’s bottom left corner.
“
1
”
indicates program number 1 (of 20).
“
ON
”
indicates the time for activation.
“
OFF
”
indicates the time for off activation.
3. Use
▲
+
and
▼
−
to change the program number according to the following sequence:
1O N
→
1 OFF
→
……
20 ON
→
20 OFF
→
d ON/OFF
(countdown)
4. After selected program, push
SET
to set week day for on and off activation.
5. Use
▲
+ to change week days. The days will be changed in the following
combinations:
MO TU WE TH FR SA SU; MO
→
TU
→
WE
→
TH
→
FR
→
SA
→
SU:
MO WE FR; TU TH SA; SA SU; MO TU WE; TH FR SA;
MO TU WE TH FR; MO TU WE TH FR SA
6. Push
SET
to confirm. The hour setting blinks in the display.
7. Use
▲
+
and
▼
−
to set hours.
8. Push
SET
to confirm. The minute setting blinks in the display.
9. Use
▲
+
and
▼
−
to set minutes.
10. Press
CLOCK
to return to normal mode.
Countdown function
Set the countdown time
The countdown interval is from 1 second to 99 hours, 59 minutes and 59 seconds.
1. When the display is in normal mode, press
▼
−
to return to the countdown function.
The display shows “d ON” or “d OFF”.
d
indicates that the countdown function is
activated.
2. Push
SET
until “ON” or “OFF” blinks on the display.
3. Use
▲
+
and
▼
−
to switch between
ON
or
OFF
.
ON
set the duration for how
long the device/output will be ON (the device/output will be turned off after
the countdown).
OFF
set the duration for how long the device/output will be OFF
(the device/output will be turned on after the countdown).
4. Push
SET
to confirm. The timer display blinks.
5. Use
▲
+
and
▼
−
to set hours.
6. Push
SET
to confirm. The minutes display blinks.
7. Use
▲
+
and
▼
−
to set minutes.
8. Push
SET
to confirm. The seconds blink.
9. Use
▲
+
and
▼
−
to set seconds.
10. Push
SET
to confirm and then push
CLOCK
to return to normal mode.
Start the countdown
1. Set the countdown time according to the instructions above.
2. Connect the device to the time switch and connect the time switch to a wall socket.
3. Push
ON/OFF
to set the time switch in AUTO mode.
4. Push
CD
to start the countdown function. “CD” will blink to confirm that
CD-mode is activated.
5. When the countdown has come to 00:00:00, the e.g. lamp turns on or off depending
on what has been programmed.
Random on and off activation
1. Connect the device to the time switch and connect the time switch to
a wall socket.
2. Push
ON/OFF
to set the time switch in AUTO mode.
3. Push
RND
. An icon with the letter “R” will appear to confirm that the RND-mode is
activated. The output is now off for 26 to 42 minutes before it randomly turns on.
The output then stays on for 10 to 26 minutes before it turns off again.
Turning the lamp on and off manually
Push
ON/OFF
to manually activate or deactivate the time switch.
ON
The voltage turns on regardless of the setting and the connected device
can be used.
AUTO
The time switch operates according to pre-set program.
OFF
The voltage turns off and the connected device cannot be used.
Safety
• The time switch is intended for use indoors and may not be used outdoors!
• Devices connected to the time switch must be constructed for the same voltage
according to the specifications below.
• The built-in batteries are fully charged after approx. 2 hours use.
• Make sure that the electrical socket that the product is plugged into is easily
accessible in case it and the connected product need to be quickly disconnected
from the mains electricity.
• Do not connect products of this type to each other.
• Do not cover the product.
Responsible disposal
This symbol indicates that this product should not be disposed of with
general household waste. This applies throughout the entire EU. In order
to prevent any harm to the environment or health hazards caused by
incorrect waste disposal, the product must be handed in for recycling
so that the material can be disposed of in a responsible manner.
When recycling your product, take it to your local collection facility or
contact the place of purchase. They will ensure that the product is
disposed of in an environmentally sound manner.
Specifications
Mains Supply
230 V AC, 50 Hz
Max load
1800 W
Operating Temperature
0–55 °C
Class
IP20
Minimum time interval
1 minute
5
6
7
8
9
10
1
2
3
4
11
1. LCD-display
2.
S
– Indication on the display
for summer time.
3.
CLOCK
– Press to return to normal mode (time).
4.
SET
– Sets time and week day and also confirms settings.
5.
▼
−
– Adjusts time, week, and program group.
6.
▲
+
– Adjusts time, week, and program group.
7.
ON/OFF
– Changes function on the time switch. ON, AUTO or OFF.
8.
RND
– Randomly activates on and off when the time switch is in AUTO mode.
9.
CD
– Starts or stops the countdown function when the time switch is in AUTO mode.
10.
RESET
– Press one time to reset the time switch to factory settings.
11. Plug socket
Use
Time display
The clock is showing 12 or 24 hour display. To change between 12 and 24 hour
display, press and hold
CLOCK
until the display changes the time format.
• At 12 hour display “AM” or “PM” is shown on the display.
• At 24 hour display neither AM nor PM is shown on the display.