1.0  General

1.1  Equipment Description
The 4115-300 Ka-band Block Upconverter converts 0.95 - 1.95 GHz up to 27.5 - 31.0 GHz in four selectable 
fixed bands. Front panel LEDs provide indication of DC Power and PLL Alarms. The L-band to RF gain is +30 
dB. Connectors are 2.92.mm for RF Out and RF Monitor, SMA for the external reference input and reference 
output and Type N (all female) for the L-band. Gain, band select, and internal 10 MHz frequency are controlled 
by the Ethernet M&C.  In AUTO, the 10 MHz reference stays in external if the external level is in the +2 to +8 
dBm range. It is powered by a 100-240 ± 10%  VAC power supply, and mounted in a 8”Wide X 6”High X 
16”Deep Weather Resistant enclosure.

NOTE: *Weather Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure/antenna hut OR 

mounted outdoors on an antenna assembly at their specified temperature ranges.  They are designed to be located “out in the 

elements” (water, sleet, snow, etc.) but they are not designed to be “submerged under” water.  If an extended temperature range is 

required, there is an Extended Temperature option (Option W21; -30˚C to +60˚C) available at an additional cost.  Contact Cross for 

quote.

 

L-BAND IN

J9

10M IN

STATUS / 

CONTROL 

ETHERNET

POWER

ALARM

J3

J4

10M OUT

FUSE

J8

AC IN

J7

F1

MODEL 4115 UPCONVERTER

RF MON

J2

RF OUTPUT

J1

.

.

.

.

.

J6

C

ROSS

 

T

ECHNOLOGIES INC.

..

....

.....

....

...

.

Model 4115-300 Ka-Band Block Upconverter Front Panel

 0.95 

to 

1.95

 GHz 

IN

11.7 to 13.2 GHz 

BP

EXT
10 M

10 M
TO
PLLS

27.5 to 31  

GHz BP

1 - 7.94
2 - 8.14 
3 - 8.40
4 - 8.90
     GHz

SW,PLL,ATT,VCC CONTROL

M&C

CONTROLLER

-20 RF 

MON

10 M
MON

15.8 to 17.8  

GHz BP

27.5 to 

31 GHz 

OUT

2
0

 dB 

C
O
U
P

2X

I

S
O
L

I

S
O
L

4115-300 Upconverter Block Diagram

REV. B 
6/01/11

V
A
R

A
T
T

1 - 10.67
2 - 10.77
3 - 11.25
4 - 11.25
       GHz 

UPCON-513 

FIGURE 1.0    Model 4115-300 Ka-Band Block Upconverter Block Diagram

4115-300 Manual, Rev. H

 

                      Page 3   

                                 11/16/15

Summary of Contents for 4115-300

Page 1: ...ed without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipmen...

Page 2: ...tive materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option...

Page 3: ...tenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be located out in the elements water sleet snow etc but they are not designed to be subm...

Page 4: ...MHz Level In Mon Band Specific LO Frequency 30 3 dB 30 to 0 dB variable in 0 5 dB Steps Gain Fc 105 95 80 75 65 1MHz 100kHz 10kHz 1kHz 100 MHz dBC Hz Phase Noise F Hz Controls Indicators Green LED Po...

Page 5: ...MS3112E14 18S Mating Cable Connector MS3116F14 18P Ethernet Conector RJF21B Mating Cable Connector RJF6G Cable interface Standard RJ45 AC Input Connector Clipper Series CL1M1102 Mating Cable Connector...

Page 6: ...d CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts max 2 Neutral 3 Ground 2 1 Message Protocol The serial format for the RS232 RS422 RS485 port is 9600 baud 8...

Page 7: ...ge 2000 to 8000 xxxxx 5 characters where aaCOxxxxx Set Int 10 MHz reference offset Range 0 to 31 xx 2 characters where aaCRxx Set RS485 address x 2 to select RS485 x 0 to select RS232 where aaCIx Set...

Page 8: ...s selected Returns aaSIx where aaSI Serial Interface x 2 if External 10 MHz reference is selected x 1 if Internal 10 MHz reference is selected Returns aaSEx where aaSE 10 MHz reference Range 0 to 300...

Page 9: ...to 99 degrees Celsius xxx 3 characters Returns aaSTxxx where aaST Internal Temperature y 0 if unit is using internal 10 MHz ref y 1 if unit is using external reference x 0 if no summary alarm x 1 if s...

Page 10: ...115 300 Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4115 300 2 4 2 Ethernet Configuration Each 4115 300 must be configured with an appropriate IP addres...

Page 11: ...delimiter dots example 192 168 192 47 Click on apply settings to apply the new settings in the device server 2 4 3 Web page M C Enter the following address in a web browser to access the M C web page...

Page 12: ...ws XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock from the Con...

Page 13: ...SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of...

Page 14: ...Figure 2 F Device Server Configuration Menu 4115 300 Manual Rev H Page 14 11 16 15...

Page 15: ...S CONTROL CONNECTOR Weatherized MS3112E14 18S 18 pin connector See Table 2 6 REF INPUT Type N female 50 0 95 to 1 95 dBm See Table 2 1 ETHERNET CONNECTOR Weatherized Standard RJ45 Ethernet Connector F...

Page 16: ...tor and Control Connector Monito Monitor and Control Connector Pinout MS3112E14 18S Conne Connector part number MS3112E14 18S Mating Mating Connector part number MS3116F14 18P Pin Signal Description A...

Page 17: ...J2 or EXT for external 10 MHz 2 to 8 dBm ref that is inserted at J2 on front panel switch S1 see Table 2 0 8 Check that a 10 MHz signal is present at the 10 MHz REF OUTPUT at the same level as the inp...

Page 18: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4115 300 Manual Rev H...