Save? When “R” is selected from 
any above menu or at the end

PUSHING MENU/EXECUTE SEQUENCE

ON POWER UP

 2483-40311
 5.00

GAIN C1 =   -10

GAIN C2 =   -10

SCROLL <>

SCROLL 

PUSH BUTTON

PUSH BUTTON

Power Up

Normal Display

Menu 1    Set Gain C1

Menu 2    Set Gain C2

Menu 3    Set Gain C3

Menu 4    Set Gain C4

Menu 5    Set Unit to
                Remote Operation

Menu 6  Set Remote Interface

Menu 7  Set RS485 Interface

SCROLL <>

SCROLL 

PUSH BUTTON

 R

 R

GAIN C3 =   -10

SCROLL <>

SCROLL 

PUSH BUTTON

 R

GAIN C4 =   -10

SCROLL <>

SCROLL 

PUSH BUTTON

 R

REMOTE OFF 

SCROLL <>

SCROLL 

PUSH BUTTON

 R

INTERFACE  485         R 

SCROLL <> 

PUSH BUTTON

NORMAL DISPLAY

G1=+11.0     G2=+11.5

G3=+14.5     G4=+16.5

SCROLL <>

SCROLL 

PUSH BUTTON

RS485 ADDR               R 

SCROLL <>

SCROLL 

PUSH BUTTON

SAVE SETTINGS       Y N 

FIGURE 2.5 Front Panel Menu Display & Sequence

2483-40311  Manual, Rev. 0 

                     Page 16

    

                                           08/01/18

Summary of Contents for 2483-40311

Page 1: ...ata drawings and other material contained herein are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of op...

Page 2: ...period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or ent...

Page 3: ...sis 2483 40311 Four 4 Channels 2483 30311 Three 3 Channels 2483 20311 Two 2 Channels 2483 10311 One 1 Channel MENU EXECUTE MODEL 2483 CROSS TECHNOLOGIES INC TRANSLATOR REMOTE POWER ALARMS G1 11 0 G2 1...

Page 4: ...ng Frequency Sense 5 ns total 970 1130 MHz out Group Delay maximum 0 dBm maximum gain Output 1 dB compression 970 to 1130 MHz Frequency 50 12 dB Impedance Return Loss 20 dB set to minimum input maximu...

Page 5: ...nternal ref H 75 BNC RF OUT 50 BNC RF IN Kx Ethernet with TCP IP Telnet W28 Available Options 75 BNC RF OUT 75 BNC RF IN Bx Ethernet with Web Browser SNMP W18 10 C to 40 C Specifications subject to ch...

Page 6: ...DB 9 PC Com Port Male DB 9 2483 40311 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 female J10 Pinouts RS 232C 422 485...

Page 7: ...ignating the channel number xxx gain to nearest 0 5 dB e g 140 14 dB Get mute setting aa iSM Returns iSMx where i 1 2 3 or 4 designating the channel number x 1 for Mute ON carrier OFF x 0 for Mute OFF...

Page 8: ...ng the channel number t channel type 0 for unused 1 for upconverter 2 for downconverter ggg gain to nearest 1 0 dB e g 25 25 dB m mute 0 mute off 1 mute on a alarm 0 for alarm off 1 for alarm on Get a...

Page 9: ...el number PLEASE NOTE The two character aa 00 31 prefix in the table below should be used ONLY when RS 485 is selected Table 1 2 2483 40311 Comma ands Commands Table 1 2 2483 40311 Commands Command Sy...

Page 10: ...space between units may be required NOTE Additional space between units is recommended if multiple Quad channel units are to be stacked in the same rack E Circuit Overloading Consideration should be g...

Page 11: ...switching 12 24 5 VDC power supply provides power for the assemblies The 2483 40311 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 2483 40311 is assembled POWER...

Page 12: ...0dBm 50 BNC Female J7 IF IN 220 to 380 MHz Input 30 to 10dBm 50 BNC Female J6 RF OUT 970 1130 MHz output 30 to 10 dBm 50 BNC Female see Table 2 2 J8 RF OUT 970 1130 MHz output 30 to 10 dBm 50 BNC Fema...

Page 13: ...ow LEDs indicates remote operation S2 MULTI FUNCTION SWITCH Vertical toggle switch that controls values in the Menu items when in program mode Does not function in the normal display mode S3 MULTI FUN...

Page 14: ...Menu Settings 5 Be sure DS6 green DC Power PSA PSB is on and DS2 red Alarm is off Figure 2 3 6 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and is inserted in the far slot in the drawer b...

Page 15: ...YES If you do not wish to save any settings you can either select Save and NO or you can NOT press the Menu Execute switch and simply do nothing for approximately 30 seconds and the unit will return...

Page 16: ...Set Unit to Remote Operation Menu 6 Set Remote Interface Menu 7 Set RS485 Interface SCROLL SCROLL PUSH BUTTON R R GAIN C3 10 SCROLL SCROLL PUSH BUTTON R GAIN C4 10 SCROLL SCROLL PUSH BUTTON R REMOTE...

Page 17: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2483 40311 Manual Rev...

Reviews: