Model 2415-x02
Multi Channel Upconverter
2415-402 Four Channel • 2415-302 Three Channel • 2415-202 Two Channel • 2415-102 One Channel
1.0 General
1.1 Equipment Description
The 2415-402 Upconverter has four individual channels, each one converts 70 MHz to 950 to 2150 MHz in 125
kHz steps using PLL in “exact frequency mode” with low group delay and flat frequency response. Synthesized
local oscillators (LO) provide frequency selection. Push button switches select the output frequency, gain, and
other parameters. Front panel LEDs provide indication of DC power, PLL alarm or Remote operation. Gain is
adjustable manually over a 0 to +30 dB range in 0.5 ± 0.5 dB steps. The frequency and gain of each channel are
also remotely selectable. Parameter selection and frequency and gain settings appear on the LCD display.
Connectors are Type F female for the RF, and BNC female for the IF and
external 10 MHz reference input and
output. The
10 MHz reference can be inserted on all RF lines. The table below shows available options.
SSPB
+24 VDC option V1, can be inserted only on the channel 1 RF line.
The 2415-402 is powered by a 100-240
±10% VAC, 47-63 Hz power supply, and is contained in a 1 3/4” X 19” X 16” rack mount chassis.
* 2415-x02, Four (4) Channels, 2415-302, Three (3) Channels, 2415-202, Two (2) Channels, 2415-102, One (1) Channel.
MENU
EXECUTE
MODEL 2415
C
ROSS
T
ECHNOLOGIES INC.
UPCONVERTER
REMOTE POWER
ALARMS
1674.125 1926.250
1926.375 2086.625
------ CH 1 -------- ------ CH 2 --------
1
2
3
4
------ CH 3 -------- ------ CH 4 --------
A
B
FRONT PANEL (2415-402 - Four Channel show)
PSA
GND
J11
J12
AND
MONITOR
CONTROL
CHANNEL 4
RF OUT
J10
J9
IF IN
CHANNEL 3
RF OUT
J8
J7
IF IN
CHANNEL 1
RF OUT
J2
VDC
ON
RF
J1
IF IN
10 MHZ REF
OUTPUT
10 MHZ IN/OUT
J4
J3
10 MHZ REF
INPUT
CHANNEL 2
RF OUT
J6
J5
IF IN
PSB
1
5
2
3
4
6
7
8
9
REAR PANEL (2415-402 - Four Channel shown with optional Ethernet)
FIGURE 1.1 Model 2415-x02 Front and Rear Panels
SW,PLL,ATT,
10M CONTROL
M&C
CONTROLLER
EXT
10MHz
INT 10MHz
10MHz
TO
VCOs
2415-402
Block
Diagram
0.8 to 2.2 HP/LP
2400 MHz BP
3.35 to
4.55 GHz
var
atten
70
MHz
IN
2470
MHz
200 MHz LP
0.95
to
2.15
GHz
OUT
SAME FOR FREQUENCY CHANNEL 2
SAME FOR FREQUENCY CHANNEL 3
SAME FOR FREQUENCY CHANNEL 4
10 MHz, std.,
DC - Opt V1
var
atten
------ CH 1 -------- ------ CH 2 --------
------ CH 3 -------- ------ CH 4 --------
1674.125 1926.250
1926.375 2086.625
FIGURE 1.2 Model 2415-x02 Upconverter Block Diagram
(Block Diagram applies to Models 2415-102, 202, 302 & 402)
2415-x02 Manual, Rev. E
Page 3
09/28/17