Cross Technologies 2415-x02 Instruction Manual Download Page 3

Model 2415-x02  

Multi Channel Upconverter

2415-402 Four Channel  • 2415-302 Three Channel  •  2415-202 Two Channel  •  2415-102 One Channel

1.0  General

1.1  Equipment Description
The 2415-402 Upconverter has four individual channels, each one converts 70 MHz to 950 to 2150 MHz in 125 
kHz steps using PLL in “exact frequency mode” with low group delay and flat frequency response. Synthesized 
local oscillators (LO) provide frequency selection. Push button switches select the output frequency, gain, and 
other parameters. Front panel LEDs provide indication of DC power, PLL alarm or Remote operation. Gain is 
adjustable manually over a 0 to +30 dB range in 0.5 ± 0.5 dB steps. The frequency and gain of each channel are 
also remotely selectable. Parameter selection and frequency and gain settings appear on the LCD display. 
Connectors are Type F female for the RF, and BNC female for the IF and

external 10 MHz reference input and 

output. The

10 MHz reference can be inserted on all RF lines. The table below shows available options.

 SSPB 

+24 VDC option V1, can be inserted only on the channel 1 RF line.

 The 2415-402 is powered by a 100-240 

±10% VAC, 47-63 Hz power supply, and is contained in a 1 3/4” X 19” X 16” rack mount chassis.

 
* 2415-x02, Four (4) Channels, 2415-302, Three (3) Channels,  2415-202, Two (2) Channels,  2415-102, One (1) Channel.

MENU

EXECUTE

MODEL 2415

C

ROSS 

T

ECHNOLOGIES INC.

UPCONVERTER

REMOTE POWER

ALARMS

1674.125  1926.250 
1926.375  2086.625  

 ------  CH 1  --------   ------  CH 2 --------

1

2

3

4

 ------  CH 3  --------   ------  CH 4 --------

A

B

FRONT PANEL (2415-402 - Four Channel show)

PSA

GND

J11

J12

AND

MONITOR

CONTROL

CHANNEL 4

RF OUT

J10

J9

IF IN

CHANNEL 3

RF OUT

J8

J7

IF IN

CHANNEL 1

RF OUT

J2

VDC 

ON 

RF

J1

IF IN

10 MHZ REF 

OUTPUT

10 MHZ IN/OUT

J4

J3

10 MHZ  REF 

INPUT

CHANNEL 2

RF OUT

J6

J5

IF IN

PSB

1

2

3

4

6

7

8

9

REAR PANEL (2415-402 - Four Channel shown with optional Ethernet)

FIGURE 1.1   Model 2415-x02  Front and Rear Panels

SW,PLL,ATT,

10M CONTROL

M&C

CONTROLLER

EXT

10MHz

INT  10MHz

10MHz

TO 

VCOs

2415-402
Block 
Diagram

0.8 to 2.2 HP/LP

2400 MHz BP

3.35 to

4.55 GHz

var

atten

70

MHz

IN

2470

MHz

200 MHz LP

0.95 

to 

2.15 
GHz

OUT

SAME FOR FREQUENCY CHANNEL 2

SAME FOR FREQUENCY CHANNEL 3

SAME FOR FREQUENCY CHANNEL 4

10 MHz, std.,

DC - Opt V1

var

atten

 ------  CH 1  --------   ------  CH 2 --------

 ------  CH 3  --------   ------  CH 4 --------

1674.125  1926.250 
1926.375  2086.625  

FIGURE 1.2    Model 2415-x02  Upconverter Block Diagram

(Block Diagram applies to Models 2415-102, 202, 302 & 402)

2415-x02  Manual, Rev. E 

                     Page 3

    

                                            09/28/17

Summary of Contents for 2415-x02

Page 1: ...el Data drawings and other material contained herein are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes o...

Page 2: ...are warranted against defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cro...

Page 3: ...2415 402 is powered by a 100 240 10 VAC 47 63 Hz power supply and is contained in a 1 3 4 X 19 X 16 rack mount chassis 2415 x02 Four 4 Channels 2415 302 Three 3 Channels 2415 202 Two 2 Channels 2415...

Page 4: ...z Frequency 75 12 dB See Table 2 2 for connector options Impedance Return Loss 70 18 MHz Frequency 75 18 dB See Table 2 2 for connector options Impedance Return Loss 97 117 90 110 80 70 65 60 Standard...

Page 5: ...CP IP Telnet W28 SSPB DC CH1 ONLY 24VDC 2 5 A V1 Available Options 140 36 MHz W140 x Ethernet with Web Browser SNMP W18 See TABLE 2 2 Connectors Impedance 10 C to 40 C Specifications subject to change...

Page 6: ...e DB 9 PC Com Port Male DB 9 2415 x02 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 female J10 Pinouts RS 232C 422 485...

Page 7: ...or 4 designating the channel number xxx gain to nearest 1 0 dB e g 14 14 dB Get mute setting aa iSM Returns iSMx where i 1 2 3 or 4 designating the channel number x 1 for Mute ON carrier OFF x 0 for...

Page 8: ...fffffgggIIIma where i 1 2 3 or 4 designating the channel number t channel type 0 for unused 1 for upconverter 2 for downconverter fffffff frequency in KHz ggg gain to nearest 1 0 dB e g 25 25 dB III i...

Page 9: ...i 1 2 3 or 4 designating the channel number xxxxxxx frequency in KHz Set Channel Gain aa iCGxx where i 1 2 3 or 4 designating the channel number xx gain to nearest 1 0 dB e g 1CGI5 sets channel 1 gai...

Page 10: ...fe operation of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply cir...

Page 11: ...s A switching 12 24 5 VDC power supply provides power for the assemblies The 2415 x02 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 2415 x02 is assembled POWER...

Page 12: ...J7 IF IN 70 MHz Input 35 to 10dBm 75 BNC J6 RF OUT 950 2150 MHz output 20 to 0 dBm Type F female see Table 2 2 J8 RF OUT 950 2150 MHz output 20 to 0 dBm Type F female see Table 2 2 J10 RF OUT 950 2150...

Page 13: ...ellow LEDs indicates remote operation S2 MULTI FUNCTION SWITCH Vertical toggle switch that controls values in the Menu items when in program mode Does not function in the normal display mode S3 MULTI...

Page 14: ...lied to the IF input 6 Set the gain for 0 to 30 0 dB See Section 2 5 Menu Settings 7 Be sure DS6 green DC Power PSA PSB is on and DS2 red Alarm is off Figure 2 3 8 AC Fuse The fuse is a 5 mm X 20 mm 2...

Page 15: ...and YES If you do not wish to save any settings you can either select Save and NO or you can NOT press the Menu Execute switch and simply do nothing for approximately 30 seconds and the unit will ret...

Page 16: ...IL YOU GO TO THE SAVE MENU AND INDICATE YOU WANT TO SAVE THE CHANGES 2 5 3 Gain Changes When you get to this menu note that the gain changes will be made as you make them but if you do not wish to sav...

Page 17: ...y Sequence OTHER SETTINGS EXT REF INT SAVE SETTINGS Y N SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL OTHER SETTINGS REMOTE ON OTHER SETTINGS INTERFACE RS232 RS485 ADDR 00 R R R R PUSHING ME...

Page 18: ...e 2415 x02 Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 2415 x02 3 2 Ethernet Configuration Each product must be configured with an appropriate IP addres...

Page 19: ...guration Manager web page In the left frame of the configuration manager click on Network to display the Network Settings screen Enter the IP address Subnet mask and Gateway address with delimiter dot...

Page 20: ...Figure 3 2 Network Settings Web Page Screen Example above shows Network Settings Screen for Model 2415 402 2415 x02 Manual Rev E Page 20 09 28 17...

Page 21: ...p ip address serial 0 setup htm where ip address is the IP address of the 2415 x02 Figure 3 3 example below shows the web page from model 2415 402 frequency converter Figure 3 3 Model 2415 x02 Web Pag...

Page 22: ...o access the SNMP configuration menu Figure 3 4 Telnet Settings in Hyper Terminal Once the Telnet connection is established you will be prompted to Press Enter for Setup Mode Press enter and a menu of...

Page 23: ...of authorized IP addresses of SNMP Managers It is not required to enter IP Addresses of SNMP Managers Figure 3 5 Device Server Configuration Menu Once you have completed you SNMP set up select item 9...

Page 24: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2415 x02 Manual Rev E...

Reviews: