background image

MODEL 2116-21#-1014 Downconverter

2114 ±50 MHz to 1014 ±50 MHz (inverted) with a 3.128 GHz local oscillator

1.0  General

1.1  Equipment Description 

- The 2116-21#-1014 Block Downconverter converts 2114 ±50 MHz to 1014 ±50 

MHz (inverted) with a 3.128 GHz local oscillator. Front panel LEDs provide indication of DC Power, External 

10 MHz, and PLL Alarm. The gain is +0 dB. Connectors are Type N female for the RF and BNC female for RF 

out and external reference input and reference output.  A three-way switch controls which 10 MHz reference is 

being  used.  In  the INT  position,  the  internal  reference is  used,  in the EXT  position,  the  external  reference  is 

used,  and  in  the  AUTO  position,  the  internal  reference  is  used  unless  a  3dBm  ±  3dB,  10MHz  signal  is 

connected  to  the  external  reference  input.    The  2116-21#-1014  is  powered  by  a  100-240  ±10%  VAC  power 

supply, and mounted in a 1 3/4” X 19” X 14” rack mount chassis.  

MODEL 2116

C

ROSS

 T

ECHNOLOGIES INC.

POWER

DOWNCONVERTER

EXT

10MHZ ALARM

FRONT PANEL

AC

GND

J8

J2

EXT 10MHZ

RF OUT

INPUT

10MHZ REF

OUTPUT

INT

EXT

AUTO

S1

J1

RF IN

J101

J11

ALARM

1

2

3

4

6

7

8

9

REAR PANEL 

 (Shown with connector option SN)

FIGURE 1.1    Model 2116-21#-1014 Front and Rear Panels

FIGURE 1.2      Model 2116-21#-1014 Downconverter Block Diagram

2116-21#-1014 Manual

 

  Page 3

    

       03/18/21

1014

±50

MHz 
OUT

1..975 to 2.175 GHz

BP

3.128

GHz

EXT

10MHz

INT

10MHz

10

MHz 

MON

AUTO

2116-21#-1014  Block Diagram

ATT

0.90 to 1.30 GHz

BP

2114

±50

MHz IN

Summary of Contents for 2116-21-1014

Page 1: ...eproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment...

Page 2: ...ogies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable f...

Page 3: ...he external reference is used and in the AUTO position the internal reference is used unless a 3dBm 3dB 10MHz signal is connected to the external reference input The 2116 21 1014 is powered by a 100 2...

Page 4: ...high X 14 0 deep Size Other 100 240 10 VAC 47 63 Hz 25 watts maximum Power DB9 NO or NC contact closure on Alarm Alarm Connector BNC femal 50 75 10 MHz Connectors N Type female 50 BNC female 50 RF L B...

Page 5: ...RF 50 N Type L BAND SN 50 SMA RF 50 SMA L BAND SS Available Connector Options 50 SMA RF 75 F Type L BAND SF 50 SMA RF 75 BNC L BAND S7 50 N Type RF 50 N Type L BAND NN 50 N Type RF 75 F Type L BAND NF...

Page 6: ...s The 2116 21 1014 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2116 21 1014 is assembled 1 PS IN PIN 1 12 VDC PIN 2 5 VDC PIN 3 5 VDC PIN 4 GROUND PIN 5 GROU...

Page 7: ...UTPUT BNC female 75 Outputs currently selected 10MHz ref signal 3 dBm 3 dB FIGURE 2 1 2116 21 1014 Rear Panel I O s shown with connector option SN TABLE 2 1 J11 Pinouts DB9 TABLE 2 1 J11 Pinouts DB9 P...

Page 8: ...ted at J2 on rear panel switch S1 Figure 2 1 6 If EXT is selected or AUTO is selected and there is a 10MHz 0 dBm signal at J2 check that DS3 yellow EXT 10MHZ is on Figure 2 2 7 Check that a 10MHz 0 dB...

Page 9: ...equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Page 10: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2116 21 1014 Manual...