SO
Switch Open
FORMAT:
(1) SOxxx,yyy
Where xxx,yyy = comma separated list of output channel numbers in ASCII
format (fan out) or a comma separated list of input channel numbers in ASCII
format (fan in)
RESPONSE:
(1) SOxxx,yyy
DESCRIPTION: This command disconnects specified outputs from all inputs. Equivalent to
SC(xxx,0)(yyy,0) for fan out matrix or SC(0,xxx)(0,yyy) for fan in matrix
SZ
Switch Size
FORMAT:
(1) SZ
(2) SZ?
RESPONSE:
(1) same as (2)
(2) SZxxx,yyy
Where xxx = number of inputs and yyy = number of outputs.
DESCRIPTION: Returns the size of the matrix switch.
TR
Report Test Results
FORMAT:
(1) TR
(2) TR?
RESPONSE:
(1) same as (2)
(2) TR”string”
where
“string” is an ASCII string composed of internal values and parameters,
and is dependent upon the configuration of the matrix
DESCRIPTION: Returns test data (BITE) results. Return string will contain pass/fail indications for
internal tests such as power supply voltages and switch cards.
EXAMPLE: Normal response might look like TR5V:P,BAT:P. This response shows the 5V and
Batteries both Pass internal monitoring
VR
Firmware Version
Returns firmware version number and date.
FORMAT:
VR or VR?
RESPONSE:
VRV1.25 Sep 06 2014 10:12:13 (typical response
)