57
Use compressed air to check that the turbine unit rotates freely
4. Use compressed air to verify that the turbine unit rotates
freely (maximum air pressure 1 BAR [15 psi]).
Every 50 Hours
Carry out the following procedure after every 50 hours
of operation:
1. Unscrew the sensor.
2. Separate the sensor from the Rapid Check unit.
Separate the sensor from the Rapid Check unit
3. Place the Rapid Check unit in a detergent bath for a
few hours.
Place the Rapid Check unit in a detergent bath
4. Remove the Rapid Check unit from detergent bath.
Use compressed air to verify that the turbine unit
rotates freely (maximum air pressure 1 BAR [15 psi]).
If necessary, replace the Rapid Check unit with a
new one.
Use compressed air to check that the turbine unit rotates freely
SECTION 7
SPRAYING INFORMATION