The pump will draw liquid from the tank and bypass 
this until such time as you open the manual taps and 
flick the main lever on the manual control unit to the 
open position. Refer to the section below AR UCM 
controller operation. 

Once the boom taps and master on/off lever on 
the manual control unit are in the open position, 
the nozzles should spray. Using the rotary pressure 
relief valve knob, you can now adjust the pressure 
to the recommended spraying pressure by rotating 
the PRV knob. Anti-clockwise rotation will reduce 
the pressure; clockwise rotation will increase the 
pressure. Using the pressure gauge on the control 
unit, you can determine the spraying pressure. For 
most boom-spraying jobs, a pressure between 1 
and 5 bar (30 to 70 psi) is the norm. The AirMix™ 
low-drift nozzles can be safely operated within a 
1-6 bar pressure range, but note that the Spray 
Quality will be influenced by your spraying pressure.

For more information on Spray Quality, you can 
access the Croplands Buyers Guide on line 
and check the chart for AirMix™ nozzles – this 
information is in the nozzle section.

Most chemical labels advise the application 
rate and spray quality for the product being 
used. Youmay wish to discuss this with your local  
agronomist if you are unsure.

If you have electric controls or an Auto-Rate spray 
controller fitted to you AgriPak linkage sprayer, 
please refer to the Croplands manual relevant to the 
model you have purchased to learn how to use this 
prior to start up. Croplands Technical support can 
also be contacted should you need assistance (see 
back page for contact details)

Flushing tank – standard on 300, 600 and 

800 litre models

A 3-way ball valve is provided on the suction line to 
allow the operator to select suction from either the 
main spray tank, or the fresh-water flushing tank.

              CAUTION

Never use the fresh water flushing or 

handwash tank for chemical use. These 

tanks are designed specifically for 

holding fresh water for either flushing the 

sprayer, or in the case of the hand-wash 

tank, for the operator to use for cleaning 

hands or the suction filter in the field.

To flush the sprayer in the field after spraying, shut 

off the boom using the liquid controls, stop the PTO 

and leave the boom in the unfolded operating 

position. Using the ball valve, select the fresh water 

flush tank. Climb back into the tractor cab, start the 

PTO and open the manual or electric control to 

allow fresh water to flow through the spraying circuit 

and the nozzles. If you have remaining spray left in 

the main tank, flush only for one to two minutes to 

flush the pump and boom lines. 

If you have finished your spraying job and the 

main tank is empty, you can flush the system for 5 

minutes, or until the flushing tank is empty, to ensure 

the system is thoroughly flushed with fresh water. It 

is recommended to do this in the field so that any 

chemical residue is deposited in the area you have 

been spraying to avoid continual deposits back at 

the spray shed site. 

A thorough tank clean once back at the shed is 

recommended if you have finished your spray 

job. Always drain the main tank when finished. To 

avoid algae build up in the fresh water tanks, it is 

recommended these also be drained and refilled 
just prior to the next spraying job. 

This will ensure your AgriPak sprayer is ready to go 
prior to its next use. To clean the filters:

 

»

 Ensure the shut-off tap is in the “off” position, or 
the shut off plug is removed from the filter housing

 

»

 Remove the filter element from the housing by 
undoing the main filter housing nut

 

»

 Clean the filter element with fresh water (note, 
if the suction filter does become blocked during 
spraying, this can be cleaned in the field by using 
the handwash tank 

 

»

 If a pressure filter is fitted (normally if the sprayer 
has electric controls fitted), also remove the filter 
cartridge and clean with fresh water

 

»

 Inspect the nozzle filters, at least one from each 
boom section, and if required, clean these in fresh 
water. The nozzles filters are up inside the nozzle 
body and can be accessed by removing the 
nozzle cap. If care has been taken to have clean 
water used for spraying, and the suction filter is 
kept clean, the nozzle filters should not block.

 
After and extended time of non-use, it is 
recommended you check the filters before your next 
spray job. Often spiders or wasps can get into the 
filter housing. 

NOTE

Always use gloves when handling filters. 

NOTE

Always clean the filters when your 

spraying job is completed. 

Summary of Contents for AgriPak LA1000

Page 1: ...OPERATORS MANUAL Croplands AgriPak Linkage Sprayers MODELS 300 Litre 600 Litre 800 Litre 1000 Litre 09 07 2016 LP OMLINK B...

Page 2: ...s e mail us and expect a reply the following morning We trust you will get years of good use from your Croplands AgriPak Linkage Sprayer Yours sincerely Sean Mulvaney General Manager CONTENTS 1 Warran...

Page 3: ...ll not accept liability for any inaccuracy in this publication or changes forthwith Terminology These terms symbols used throughout this manual About This Manual This manual provides setting up inform...

Page 4: ...ign Homemade parts may look the same but might be dangerous in operation Follow the chemical manufacturers precautions before cleaning the sprayer Exposure to chemicals could result in serious illness...

Page 5: ...roduct What is its poisons schedule or toxicity What safety precautions are required What is its persistence and withholding period What is its mode of action Will it be a hazard to neighbouring crops...

Page 6: ...ed for most spraying applications Operator Safety When handling pesticides always use elbow length gloves long clothes and above all a respirator If you and your clothing become contaminated with spra...

Page 7: ...ns for controllers booms hosereels spray guns foam markers GPS systems refer Croplands Optima Buyers Guide on line Pump model Serial number The Pump model pump serial number is located on the pump its...

Page 8: ...P 76 4 20 bar AR140LFP 132 9 15 bar AR30 35 40 bar AR503 54 1 40 bar Tank lid strainer 18 mesh Suction filter 50 mesh Boom nozzle strainers if fitted 50 mesh Optional in line pressure filter s 100 mes...

Page 9: ...m manual or www croplands com au MAX level Hydraulic boom height adjuster or lift device For remote lifting of the spray boom using tractor hydraulic remotes Shown is lift for LP 800 MAX booms for mor...

Page 10: ...guards to the tractor the pump PTO guard Raise and lower the sprayer to check that the tubes of the PTO overlap by at least 1 3 of their length and not less than 150mm in all operating positions Start...

Page 11: ...rayer in the field after spraying shut off the boom using the liquid controls stop the PTO and leave the boom in the unfolded operating position Using the ball valve select the fresh water flush tank...

Page 12: ...include TeeJet range of spray guns Spot Gun 300 Talk to your dealer if you want a different spray gun for a specific purpose To operate the RL10 spray lance or Turbo400 spray gun start the sprayer an...

Page 13: ...at will depend on the conditions terrain and product being applied In general speeds of 5 to 15 km hr are most often within the range for linkage spraying Spray Quality Spray quality is becoming extr...

Page 14: ...Litres per minute L min along with spraying pressure CAUTION Check the current Croplands Optima Buyers Guide for Nozzle information or purchase a copy of the Nufarm Spraywise Spray Application Guide C...

Page 15: ...9 199 166 142 125 100 83 0 62 3 2 0 0 980 230 192 165 144 115 96 0 72 0 3 0 1 200 283 236 202 177 142 118 88 5 4 0 1 386 326 272 233 204 163 136 102 5 0 1 549 365 304 261 228 182 152 114 6 0 1 697 401...

Page 16: ...connections do not leak Repair or replace damaged components 7 Read and follow the instructions on the chemical manufacturers label before mixing and adding chemicals to the spray tank For safety inf...

Page 17: ...PTO drive shaft is disconnected check for holes or tears Clean the suction filter every time the tank is filled and at the end of the days spraying Make sure O rings are in good condition and grease...

Page 18: ...35 34 18 09 2016 LP OMLINK B LA300 LINKAGE 300 LITRE WITH MBX04 BOOM HOSE REEL NOTE This parts list is indicative of this model sprayer For further parts information refer to www croplands com au...

Page 19: ...37 36 18 09 2016 LP OMLINK B LA600 LINKAGE 600 LITRE WITH AR80 PUMP NOTE This parts list is indicative of this model sprayer For further parts information refer to www croplands com au...

Page 20: ...38 18 09 2016 LP OMLINK B LA800 LINKAGE 800 LITRE WITH MAX10 BOOM LEVELLER LIFT HOPPER NOTE This parts list is indicative of this model sprayer For further parts information refer to www croplands com...

Page 21: ...41 40 18 09 2016 LP OMLINK B LA1000 TANK AND FRAME ONLY NOTE This parts list is indicative of this model sprayer For further parts information refer to www croplands com au...

Page 22: ...43 42 18 09 2016 LP OMLINK B LIFT DEVICE FOR 600 AND 800 LITRE AGRIPAK MODELS NOTE This parts list is indicative of this model sprayer For further parts information refer to www croplands com au...

Page 23: ...R M10 FLAT WASHER ZP 24 16 M10NNUT M10 NYLOC NUT HT ZP 20 D E F C 1 2 3 4 B A 3 2 1 5 C D 4 6 7 8 A B HYDRAULIC LIFT KIT 800LT LP800 HYD WEIGHT N A N A A3 SHEET 1 OF 1 SCALE 1 10 DWG NO TITLE ISSUE DO...

Page 24: ...45 44 18 09 2016 LP OMLINK B MBX06 BOOM NOTE This parts list is indicative of this model sprayer For further parts information refer to www croplands com au...

Page 25: ...47 46 18 09 2016 LP OMLINK B MAX12 METRE BOOM WITH SELF LEVELER NOTE This parts list is indicative of this model sprayer For further parts information refer to www croplands com au...

Page 26: ...x 1800 623 778 e mail sales croplands com au website www croplands com au NEW ZEALAND Croplands Equipment Ltd PO Box 2004 Stotford Lodge Hastings 4120 Location 1422 Omahu Road Hastings 4120 New Zealan...

Reviews: