![Cronyx Qlink-3000/2E1 Installation And Operation Manual Download Page 8](http://html.mh-extra.com/html/cronyx/qlink-3000-2e1/qlink-3000-2e1_installation-and-operation-manual_2687181008.webp)
Qlink-3000 Multiplexing modem
1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567
1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567
Copyright © 2003 -2005 Cronyx Engineering
8
1.4. Technical specifications
Link interface
Link requirements .......................................... Unloaded twisted pair
Link data rate .................................................. 208 kbit/s to 2320 kbit/s
Link length ..................................................... Up to 10 km with a 0.6 mm wire strand
diameter,
up to 7.6 km with a 0.4 mm wire strand
diameter
Connector ....................................................... RJ type (female, 8 pins)
Encoding ......................................................... TC-PAM
Transmission path synchronization................ Internal (from an internal clock-pulse
oscillator)
From Port (from the receiving path of
the E1 port)
Overvoltage protection ................................... SIDACtor
Overcurrent protection ................................... Fuse
E1 interface (2048 kbit/s)
Connector ....................................................... RJ-48 (female)
Link impedance .............................................. 120 Ohms, balanced (twisted pair)
Cycle structure................................................ according to G.704, or transparent stream
transmission (Unframed G.703)
Signal level at the receiver input .................... 0 to -43dB, up to 2 km over 22AWG
(0.6 mm) twisted pairs
Jitter attenuator ................................................ in the receiver path
Data encoding ................................................. HDB3
Error detection ................................................ Bipolar violation
Overvoltage protection ................................... TVS
Overcurrent protection ................................... Fuse