Cron TP26G+ User Manual Download Page 17

 

 

 

6.4.2

 

Slip Paper Collector connec on

6.4 Slip Paper Collector

6.4.1

 

Slip Paper Collector structure

6.4.3

 

Slip Paper Collector unit maintenance

6.5.3

 

Using the Straight In-line Bridge

6.5.4

  

Straight In-line Bridge maintenance

6.5

 

 Straight In-line Bridge

6.5.2

 

Straight In-line Bridge connec on

6.5.1

 

Straight In-line Bridge structure

Air outlet 

(nozzles)

Slip paper rollers

Power control cable connec on

Fans

1

6

2

3

4

5

1

6

2

3

4

5

Chapter 6: Op onal Devices

  The Slip Paper Collector is an op onal device used to separate slip papers on the H model CTP device, remove 
and organize slip papers effec vely, increase the number of single delivery, and reduce the manual interven on on 
slip paper handlings.

A ach  the  Slip  Paper  Collector  unit  under  the  slip  paper  outlet  path  according  to  the    screw  holes  posi on 
provided, then connect the power control cable to the port shown below, 

a) Regularly clean the air outlet nozzles
b) Regularly check the condi ons & cleanliness of the slip paper rollers
c) Regularly check the transmission gears lubricants& condi ons
d) Regularly check the fans opera on

  The  Straight  In-line  Bridge  is  op onal  peripheral,  a aches  to  the  host  CTP  device  for  transpor ng  the  CTP 
exposed plate output to the processor unit, or it can be a temporary single plate stacker.

  a) Note: when ordering the Straight In-line Bridge to be bundled with the 
host CTP device, reserved BGP connector port will be replaced with cable 
connec on port for Straight In-line Bridge connector.
  b) USB port connec on for host CTP device TP26 / TP36 / TP46 / TP60 
models can be located on the same connec vity panel as shown in below;
    c)  For  TP72CTP  device,  the  Straight  In-line  Bridge  connector  is  located 
lower le  underneath where the bridge installed.

  a) Plate Stoppers is closed (flat): bridge is in full working mode. Plate will be transported through the bridge into 
the processor unit;
  b) Plate Stoppers is opened (flip up): convert bridge become atemporary single plate stacker. 

  a) Regularly clean the conveyor belt, conveying the upper plane 
  b) Regularly check bridge level(height) and posi on against CTP & processor 
  c) Regularly check the working mode is valid.

Conveyor belts

Plate stoppers

Bridge connec on cable port

TP72cable connec on port

Bridge installa on bracket

Bridge support arms

33

32

SIMPLE AND DIRECT  

 STEADY   

 MAJOR

SIMPLE AND DIRECT  

 STEADY   

 MAJOR

Summary of Contents for TP26G+

Page 1: ...LE AND DIRECT STEADY MAJOR Hangzhou CRON Machinery Electronics Co Ltd Jinyi Road 875 Xiaoshan Economic Technological Development Zone Hangzhou 311215 P R China TEL 0571 82838989 FAX 0571 82838877 www...

Page 2: ...Power requirement 06 2 4 Power connection wiring 06 2 5 Safety and Caution labels 08 2 6 Safety Information 10 Chapter 6 Optional Devices 6 1 Built in Punching 28 6 2 BGP Punch Bridge 29 6 3 TPV Dedus...

Page 3: ...trol system and other components b Depends on applica ons CTP can be categorized as Newsprint CTP Resolu on 1200 1800dpi Commercial CTP Resolu on 1800 2800dpi CommercialNews CTP 1500 2540dpi c There a...

Page 4: ...55 50 98 70 90 144 815 1150 1280 1650 2480 Rated power kw Power supply requirements Device Model TP26H TP26G TP36H TP36G TP46H TP46G TP60H TP60G TP72H TP72G 5 3 4 3 5 6 4 5 5 6 4 5 6 6 5 3 8 8 7 8 200...

Page 5: ...h bare hands Do not operate Equipment cover opening or closing be carefulof head collision Do not look straight intothe laser beam Do not look straight Do not touch the drum while it is rota ng the dr...

Page 6: ...d be placed in order Avoid overhead collision during equipment opera on This device is not intended to be used in an explosive or poten ally explosive atmosphere Fireworks is prohibited near the occas...

Page 7: ...n site Depend on CTP series model standard packing could uses 1 to 2 crates Single Crate Single Crate Single Crate Customers must provide forklift or crane with minimum load bearing for more than 2000...

Page 8: ...layers Cut the foil bag at the bo om in circle then remove foil bag Figure 4 Be careful not to scratch the equipment while cu ng the foil bag Then unscrew the hex screws 8 M6 10 unscrew the nut 4 M10...

Page 9: ...cket of the device and pay special a en on when removal Handle with care and avoid scratches to the Encoder Strip gold color that a ached at the side of the panel along the guide rail Remove both piec...

Page 10: ...gn it against the processor you can obtain current drum vacuum pressure value and the pressure sensor output status Current device coolant volume can be observed through the observa on window If the c...

Page 11: ...our computer s CD ROM drive and run the HDI Setup exe le c Follows the so ware installa on steps to install the LaBooso ware and dongle driver A er installa on is completed successfully the computer d...

Page 12: ...er right corner of the so ware 5 3 6 Newly installed so ware rst need to setup the ini al template click the New green bu on at lower le to create and setup an ini al new template Setup a template siz...

Page 13: ...resolution thickness Example 510x400 2400 0 135 Set the resolution for the template to work with Different model s con guration available resolution may be different Set the material used in the temp...

Page 14: ...Please refer to the LaBoo User s Manual for detail so ware opera on a Place the plate accordingly on the loading table align plate to right side to be close to the plate centering gauge and leave abo...

Page 15: ...punching c For plate Entrance direc on or Exit direc on No need to set or apply if using Embedded punching d Mold selec on Die punch select the correspondent Die Punch set for used with the current w...

Page 16: ...ripheral device used to remove the dust generated during plate media exposure carried out on a CTP device a Pipe connec on connect vacuum pipe hose 32 to the TPV pipe inlet connector and the host CTP...

Page 17: ...check the fans opera on The Straight In line Bridge is op onal peripheral a aches to the host CTP device for transpor ng the CTP exposed plate output to the processor unit or it can be a temporary si...

Page 18: ...on pressure Lo Mid Hi mode according to the size of the media and slip paper weight used in the Autoloader Connec vity panel on Host CTP Connec vity panel on Autoloader 6 6 4 Autoloader device opera...

Page 19: ...1 JDF_JDF 75 HSCB 109090 TP72H 2233 QB SN6 8 40 TP72H 2277 For Paper Collector Component Part Name Amount Drawing No No 3 Loading Table Arm 2 1 TP72H 2232 Angle Seat Die Cas ng 4 HSCB 109090 Square Nu...

Page 20: ...le screw M6X12 to connect the simple auto loader table to the support plate block b The gap is located in the non beam measurements 4 Screw the front and back sides of the auto loader table with screw...

Page 21: ...d drum surface at any time if found dusty a Open the front cover of the device you can observe the plate pressing roller mounting roller and drum surface conditions and its mechanism components please...

Page 22: ...he use of alcohol acetone and other liquids while wiping the encoder strip as this will damage the encoder s marks coating No Attri bute 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 Head Clamp s...

Page 23: ...parameters 33 Read device parameters failed maybe version is not correct Read device parameters again or contact engineer 34 Reset without engineer Contact engineer 35 Please adjust the focus Check an...

Page 24: ...K152 CO M 022028431 Zero position sensor for scanning platform L R FULSE RT18 3210A 029083878 To limit excessive current flows prevent wires from heating up and burns 1 2 3 4 5 6 7 DESCRIPTION PICTURE...

Page 25: ...in Main unit Round Belt1055 060203502 Output tray converying belt 8 9 Bundled with new machine Bundled with new machine Parts Name Parts No Details Parts Name Parts No Details Parts Name Parts No Det...

Page 26: ...Chapter 10 Appendix 10 1 Wiring Diagram 51 50 SIMPLE AND DIRECT STEADY MAJOR SIMPLE AND DIRECT STEADY MAJOR...

Page 27: ...Chapter 10 Appendix 53 52 SIMPLE AND DIRECT STEADY MAJOR SIMPLE AND DIRECT STEADY MAJOR...

Page 28: ...Chapter 10 Appendix...

Page 29: ...52 53 Chapter 10 Appendix SIMPLE AND DIRECT STEADY MAJOR SIMPLE AND DIRECT STEADY MAJOR...

Page 30: ...54 55 Chapter 10 Appendix SIMPLE AND DIRECT STEADY MAJOR SIMPLE AND DIRECT STEADY MAJOR...

Page 31: ...56 57 Chapter 10 Appendix 10 3 46 60 Wiring Diagram SIMPLE AND DIRECT STEADY MAJOR SIMPLE AND DIRECT STEADY MAJOR...

Reviews: