GENERAL MAINTENANCE
CHECK/CHANGE AIR CLEANER ELEMENT
!
WARNING: Never run the generator without the air
cleaner element as damage to the engine may occur.
• The air cleaner must be changed when the output of
engine decreases or if the exhaust colour looks darker
than normal.
1. Loosen the wing nut,
detach the cover and
remove the air cleaner
element.
2. Wash in warm water. DO
NOT wash with detergent.
3. Squeeze thoroughly and
dry with a clean cloth.
4. Saturate in clean engine oil. Squeeze in a clean,
absorbent cloth to remove
all excessive oil.
5. Place element back in the
air cleaner and reattach the
cover. Tighten wing nut.
CHECK/CHANGE FUEL FILTER
!
WARNING: Change filter regularly to insure maximum
engine output.
• CLEAN FILTER - Every 6 months or 300 hours.
• REPLACE FILTER - Every year or 1000 hours.
ADJUSTMENTS
!
WARNING: Tampering with the factory set governor
will damage your generator and void your warranty.
CHECK BATTERY / CHARGING BATTERY
• Before starting check battery for damage. Battery fitted
is maintenance-free, check for green light on battery to
ensure it is charged. If battery requires charging use a
compatible battery charger. Battery type 12v 36ah.