SPECIFICATIONS 

15 

Blood Pressure Monitor 
Model:     CN-205C,CN-805C,CN-806C 
Display: Digital display system 
Measurement method: Oscillometric 
Pressure unit: kPa  / mmHg 
Measurement range:

 

0  40kPa  / 0 300mmHg

 

Intrinsic error: 0.5kPa  /  3.75mmHg 
Pulse rate range:40 200beats/min 
Battery size: R6(AA) 
 

Model Cuff 

type Inflation Power 

source 

Weight 

CN-205C Upper 

arm  Manual  DC3V 

300g 

CN-805C Upper 

arm  Auto 

DC6V 

560g 

CN-806C Wrist 

  Auto  DC3V  390g 

Battery life CN-250C   approx1000times; 
                     CN-805C/CN-806C  approx.300times 
 

 
 
 
 
 

Specifications and design are subject to change without notice. 

Summary of Contents for CN-205C

Page 1: ...CRNE DIGITAL Blood Pressure Monitor Model CN 205C CN 805C CN 806C User s Guide UMX05EE003...

Page 2: ...ove when taking your blood pressure 3 If you are wearing a shirt which might restrict circulation in your upper arm remove your shirt before taking your blood pressure 4 Since exercise eating drinking...

Page 3: ...tension excitement physical activity cold surroundings and tobacco all cause the blood pressure to rise Feeling of calmness and happiness warm weather and alcohol in small quantities cause the blood p...

Page 4: ...PARTS IDENTIFICATION 1 CN205C CN805C Power button Air Connector Lcd Air Connector Cuff Bulb Auto Deflation Valve Tube Tube Note CN 805C CN 806C with Auto Inflation function...

Page 5: ...PARTS IDENTIFICATION 2 CN806C SET MODE START ON OFF LCD...

Page 6: ...PARTS IDENTIFICATION 3 CN205C CN805C LCD AREA Systolic Pressure Diastole Pressure Blood Pressure Unit CN806C LCD AREA Systolic Pressure Diastole Pressure Blood Pressure Unit...

Page 7: ...r 2 Insert the tow batteries 3 Re attach the battery cover Note CN805 need four batteries Replace the batteries when 1 The battery replacement indication shown appears in the display 2 When nothing ap...

Page 8: ...OWER SUPPLY 5 CN806C...

Page 9: ...he power button 1 Be sure the blood pressure is switched off 2 Press and hold the power button for 3 Sec The pressure unit will appears in the display kPa or mmHg 3 Release the power button Note If re...

Page 10: ...und your upper arm about 2 or 3 cm above the joint of your elbow 2 Wrap the pressure cuff closely around your arm 3Place your elbow on a table and extend your hand straight out on the table Relax your...

Page 11: ...und your wrist about 5 10 mm above the joint of your wrist 2 Wrap the pressure cuff closely around your wrist 3Place your elbow on a table and extend your hand straight out on the table Relax your ent...

Page 12: ...on mark appears Please press and hold the Auto deflation valve button until the inflation mark appears 3 Squeeze the bulb inflate the cuff as rapidly as possible Inflation the cuff to a value more tha...

Page 13: ...on 6 When the deflation mark appears press the Auto deflation valve button release all air from the cuff 7 The display will automatically alternate between your pulse rate and your blood pressure Note...

Page 14: ...ir Batteries are dead Replace with new batteries The rate of pressure drop is not correctly Check the air connector and Auto deflation valve The air release rate must be 3 4mmHg per second Nothing app...

Page 15: ...s are tending to rise or tending to decrease When repeated measurements result in different blood pressure values When measurements are taken repeatedly the blood flow changes and the measurement valu...

Page 16: ...e standard blood pressure every day In evaluating blood pressure values do not attempt to do it by yourself Have the readings interpreted by your physician Blood pressure classification chart of the W...

Page 17: ...areas where dust collects or where it will be exposed to direct sunlight 3 Since the case for the main unit is made of a special plastic remove any moisture with a soft cloth 4 If you do not plan to u...

Page 18: ...0 40kPa 0 300mmHg Intrinsic error 0 5kPa 3 75mmHg Pulse rate range 40 200beats min Battery size R6 AA Model Cuff type Inflation Power source Weight CN 205C Upper arm Manual DC3V 300g CN 805C Upper arm...

Page 19: ...CRNE...

Reviews: