Critical Environment Technologies YESDUST Operation Manual Download Page 10

10 

© 2015 All rights reserved. Data subject to change without notice. 

YESDUST - Operation Manual 

Rev. D | 2015.04

4 SENSOR SPECIFICATIONS

4.1 Sensor Specifi cations

Particulate

Type

Highly sensitive, focused, infrared light beam. Self aspirated, 
convection.

Warm-Up Time

1 minute

Particle Size Range

1 - 10 microns

Response Time (T

90

)

< 30 seconds

Operating Temperature 0°C to 45°C (32°F to 113°F)
Operating Humidity

0 - 95% RH non-condensing

Expected Life Span

Infrared light source estimated to be seven years.

Resolution

250 particulates / cubic foot

Sample Method

Diff usion

Measurement Range

7000 ug / m

3

Summary of Contents for YESDUST

Page 1: ...Operation Manual www critical environment com YESDUSTParticulate Sensor Rev D 2015 04...

Page 2: ...Description 8 2 2 Key Features 8 3 INSTRUMENT SPECIFICATIONS 9 3 1Technical Specifications 9 3 2 Standard Enclosure Dimensions 9 4 SENSOR SPECIFICATIONS 10 4 1 Sensor Specifications 10 5 FEATURES FUNC...

Page 3: ...2015 All rights reserved Data subject to change without notice 3 Rev D 2015 04 YESDUST Operation Manual 6 2 LED Patterns 17 7 MAINTENANCE 17 8 TROUBLE SHOOTING 17...

Page 4: ...n the following pages This product must be used according to instructions indicated in this manual This instrument has not been designed to be intrinsically safe For your safety do not use it in class...

Page 5: ...t include third party trouble shooting costs or freight to from the manufacturer s facility CETCI s liability is limited to replacement or repair of the equipment manufactured Due to ongoing research...

Page 6: ...e held responsible for any damage incurred during shipping to our facility 1 4 Copyrights This manual is subject to copyright protection all rights are reserved Under international and domestic copyri...

Page 7: ...rove its products and their documentation the manufacturer reserves the right to make changes at any time without notice Revised copies of this manual can be obtained by contacting CETCI or visiting w...

Page 8: ...ngs are displayed as another sensor on the LCD display of theYES multi channel monitor and are also data logged to theYES multi channel monitor internal flash card if utilized YESDUST counts particula...

Page 9: ...General Purpose ABS Weight 450 g 1 0 lbs Size 4 6 x 6 1 x 2 4 118 mm x 156 mm x 60 mm ELECTRICAL Power 9V wall adapter for rechargeable Nickel Hydride rechargeable battery pack Battery Life 16 hours c...

Page 10: ...e focused infrared light beam Self aspirated convection Warm UpTime 1 minute Particle Size Range 1 10 microns ResponseTime T90 30 seconds OperatingTemperature 0 C to 45 C 32 F to 113 F Operating Humid...

Page 11: ...rights reserved Data subject to change without notice 11 Rev D 2015 04 YESDUST Operation Manual 5 FEATURES FUNCTIONS 5 1 Exterior Enclosure NUMBER FEATURE FUNCTION Screws Secures face plate Label Lex...

Page 12: ...ration Manual Rev D 2015 04 5 2 Interior System Layout NUMBER FEATURE FUNCTION Nickel Hydride Rechargeable Battery Power source Data Out Port Connects to theYES multi channel monitor Vents Allows air...

Page 13: ...ESDUST Operation Manual 5 3 Exterior Sides NUMBER FEATURE FUNCTION Data Out Connects to theYES multi channel monitor Vents Allows air flow Comm LED Indicates communication status Charge LED Indicates...

Page 14: ...the batteries before using Observe polarity when reinstalling batteries For proper operation theYESDUST must be placed in a vertical position Before use the sensor requires a one minute warm up 6 1 O...

Page 15: ...is powered off before connecting the YESDUST Step 1 Connect the included communications cable to the DATA OUT port on theYESDUST Step 2 Connect the other end of the cable to the AUX port on theYES mu...

Page 16: ...adapter to the 9VDC jack on theYESDUST Step 2 Turn the switch to the OFF position Step 3 The CHARGE light will turn amber while the batteries are charging Once complete the CHARGE light will turn gree...

Page 17: ...arge replace them with 4 new rechargeable AA nickel metal hydride batteries YESDUST won t communicate withYES Multi channel Monitor 1 Check that the interface cable is undamaged 2 Check that the inter...

Page 18: ...18 2015 All rights reserved Data subject to change without notice YESDUST Operation Manual Rev D 2015 04 NOTES...

Page 19: ...2015 All rights reserved Data subject to change without notice 19 Rev D 2015 04 YESDUST Operation Manual NOTES...

Page 20: ...tageWay Delta BC V4G 1M3 Canada Toll Free 1 877 940 8741 Tel 1 604 940 8741 Fax 1 604 940 8745 www critical environment com 2015 Critical EnvironmentTechnologies Canada Inc All rights reserved Data in...

Reviews: