49
Part Number
YPO36-12/40A
YPO36-24/30A
YPO36-36/20A
YPO36-48/15A
Model
36-12V/40A
36-24V/30A
36-36V/20A
36-48V/15A
Recommended battery bank *
300-500Ah
200-400Ah
150-250Ah
100-200Ah
Input
Voltage
30V -48V
30V -48V
30V -64V
30V -64V
Maximum current
20A
25A
25A
25A
Nominal Power
570W
860W
860W
860W
Efficiency
96% typique
Input fuses
2 x 20A /80V
2 x 20A /80V
2 x 20A /80V
2 x 20A /80V
Output
Number of battery bank
1
rated current
40A
30A
20A
15A
Charging curve
IU or IUoU through internal push-button or CAN-BUS (Boost, Absorption,
Floating and Refresh
–
factory setting)
Battery type
Lead sealed as factory setting - Other choices through internal setting:
gel, AGM, calcium lead, lithium, stabilized power supply, etc.
Boost voltage (default)
14.4VDC
28.8VDC
43,2VDC
57.6VDC
Floating voltage (default)
13.8VDC
27.6VDC
41,4VDC
52.2VDC
Regulation tolerance
< 2% (at rated conditions)
Peak to peak ripple and noise
< 2% (at rated conditions)
Automotive fuse
2 x 20A /80V
2 x 20A /80V
2 x 20A /80V
2 x 20A /80V
Environment
Cooling
Natural (fanless)
Operating temperature
From -20°C to +60°C, derating above 60°C.
Above 65°C, current limitation
Storage temperature
From -40°C to +70°C
Relative humidity
up to 70% (95% without condensation)
Casing
Length, height, depth / Weight
236 x 180 x 96 mm / 2.2kg
Fixing center distance
219 x 155 mm
Fixing screw (wall)
4 off M5 round head screws
Protection factor
IP22
PCB protection
Water-repellent varnish (marine environment)
Standards
CE declaration of conformity
Available on request
CE / EMC
EN61204-3
CE / Security - Others
EN60335-2-29. Pending E-marking.
Protections
Polarity reversal, short-circuit, abnormal overheating
* Battery capacity recommended for lead type batteries, ratio C/10. Consult us for lithium batteries.