40
3.3.8
Programming field 7 : output current limitation
Setting
Output current limitation
1
10%
2
20%
3
30%
4
40%
5
50%
6
60%
7
70%
8
80%
9
90%
10
100%
3.3.9
Programming field 8 : select thermal probe for alternator
This function enables to protect the alternator from excessively high temperatures. Over a programmable
temperature threshold, the output current decreases.
Setting
Maximum external probe temperature
0
Disable
1
70°C
2
80°C
3
90°C
4
100°C
5
110°C
Iout = Nominal current
Output Current
Input start-up
voltage
Iout = 0A
Input Voltage
0.5V ( for 12V input )
1.0V ( for 24V input )
1.5V ( for 36V input )
2.0V ( for 48V input )