4
WWW.CRISTEC.FR
switch
is
opened.
Normally
in
this
case
the
status
led
is
lid
green
and
the
output
is
switched
on.
Depending
on
the
battery
voltage
the
led
status
can
be
different.
Without
using
the
switch
input,
the
voltage
guard
will
just
function
as
a
low
voltage
protection
for
your
battery.
Explanation
status
LED
Green
:
The
battery
voltage
is
ok.
Output
is
switched
on.
Green
blinking
:
Flashing
four
times
per
minute,
optional
panel
switch
is
closed
and
the
consumers
are
switched
off.
Orange
:
The
battery
voltage
is
lower
than
the
set
prealarm
Red
blinking
:
Output
is
switched
off
because
of
high
or
low
voltage
or
overload.
Buzzer
The
internal
buzzer
sounds
by
variable
intervals
before
reaching
the
shut
off
point.
The
interval
between
the
sounds
will
be
shorter
with
every
repetition.
Pauses
between
alarm
pulses:
600s
‐
300
s
‐
150s
‐
75s
‐
38s
‐
19s
‐
9s.
Technical
specifications
Rated
current
(constant)
:
70
A
Max
current
(10s
@
20C°)
:
140
A
Voltage
:
12
and
24
VDC
Input
voltage
range
:
8
‐
31
VDC
Consumption
:
>
2mA
(LED
Off)
Presentation
:
Plastic
housing
with
external
fixings
–
IP51
Connection
:
On
threaded
roads
Dimensions
(l
x
h
x
e)
:
100
mm
x
89.2
mm
x
43
mm
Weight
:
0,21
Kg
Operating
temperature
:
from
‐
10°C
to
+60°C
Storage
temperature
:
from
‐
20°C
to
+85°C
12V
low
voltage
adjustment
:
9
‐
12
VDC
12V
overvoltage
threshold
:
15,5
VDC
24V
Low
voltage
adjustment
:
18
‐
24
VDC
24V
overvoltage
threshold
:
31
VDC
1
WWW.CRISTEC.FR
Voltage
Guard
–
70
The
best
solution
to
protect
your
battery
against
:
Deep
discharge
Overvoltage
Overload
Presentation
The
voltage
guard
protects
your
battery
in
order
to
increase
its
duration
life.
It
provides
a
constant
low
voltage,
overvoltage
and
overload
protection.
When
you
battery
reaches
the
pre
‐
set
low
voltage
the
voltage
guard
will
disconnect
automatically
the
DC
consumers.
DC
consumers
will
be
switched
on
again
automatically
when
battery
voltage
increases
and
when
defined
threshold
is
reached.
The
system
will
operate
the
same
say
way
for
over
‐
voltage.
Low
voltage
threshold
can
be
selected
from
external
DIP
switches.
The
over
‐
voltage
value
is
fixed.
The
system
can
be
used
as
manual
main
switch.
The
output
is
turned
off
when
the
switch
is
closed.
In
this
mode
the
voltage
guard
will
only
operate
as
battery
low
voltage
protector.
The
voltage
guard
has
an
integrated
buzzer
and
LED
to
monitor
its
operating
state.
It
is
complaint
with
all
Lead
battery
types
:
wet,
sealed,
gel,
AGM,
Calcium,
etc.