CPS3-3M-DED
21
Model
Battery cable
cross-section
Diameter of the
terminal hole
CPS3/12-80
25mm²
6mm
CPS3/24-60
16mm²
6mm
CPS3/24-75
25mm²
6mm
CPS3/48-30
10mm²
6mm
The installer should choose the type ofcable (H07-VK,
MX…) according to the type ofapplication and the
applicable standards.
The cable bushings or glands must remain on the lower
side ofthe case to avoid the linking cables being
damaged on the metal walls ofthe case and to
guarantee insulation between the active conductors and
the electrical exposed conductive part.
3.2.4. Cable linking the earth to the installation
The charger's case should be connected to the installation's earthing system in accordance with current standards
governing the relevant application.
To that effect, connect the installation-to-earth cable to the earthing screw located inside the charger (see chapter
“user interface area”).
This cable's cross-section should be at least 2.5mm², type HO7-VK and equipped with an appropriate terminal.
3.2.5. Precautions regarding electromagnetic disturbance generated by the appliance
Use shielded cables for all the connections (*). The shielding should be earthed at both the transmitting and the
receiving ends.
Keep cable length and shielding connections down to a minimum.
Route cables as close as possible to conductive parts ("loose" cables or loops should be avoided – cables should be
flattened against conductive parts).
Keep power cables separate from battery cables.
Keep power cables separate from control cables (at least 200mm).
The cables should only supply power to this appliance; any branch-offor short-out intended to power another
appliance are prohibited.
(*) This is a recommendation for installation rather than an obligation.
The installing electrician should decide whether or not to use shielded cable
depending on the EMC environment.
3.2.6. Cabling principle
3.2.6.1. Cabling type
3.2.6.2. Other type of installation
Refer to appendix 3.
www.busse-yachtshop.de | [email protected]
Summary of Contents for CPS3 12V/80A
Page 13: ...CPS3 3M DED 13 5 2 CPS3 24V 75AET CPS3 48V 30A www busse yachtshop de info busse yachtshop de...
Page 26: ...CPS3 3M DED 26 5 2 CPS3 24V 75AET 48V 30A www busse yachtshop de info busse yachtshop de...
Page 39: ...CPS3 3M DED 39 5 2 CPS3 24V 75Aund 48V 30A www busse yachtshop de info busse yachtshop de...
Page 52: ...CPS3 3M DED 52 5 2 CPS3 24V 75Ay 48V 30A www busse yachtshop de info busse yachtshop de...
Page 65: ...CPS3 3M DED 65 5 2 CPS3 24V 75Ae 48V 30A www busse yachtshop de info busse yachtshop de...
Page 75: ...www busse yachtshop de info busse yachtshop de...
Page 76: ...www busse yachtshop de info busse yachtshop de...