DIESEL GLOW PLUG DELAY 

 

This feature provides a solution for diesel vehicles without having to connect to the Glow Plug-“Wait to Start Circuit”. 
This may be needed for various reasons.  If your vehicle does not have a viable “Wait to Start Circuit”, or you cannot 
locate and identify the circuit, then change your system to “Diesel Glow Plug Delay” mode.  You can choose from a 
selection of “pre-cranking” delay times.  Once this mode is activated, the system will NO LONGER monitor the PINK 
glow plug input wire and will use a delay setting chosen by the installer in the option chart. 

 
 

NOTES: This feature is OFF by default and must be programmed before use.  Once this feature is turned ON, the Pink 
Glow plug input wire is not used.  The Remote start unit will always wait the programmed time before cranking EVEN IF 
the glow plug warms up first.  There are 3 different Delay times available for use: 10, 20, or 30 seconds.  SEE OPTION 
PROGRAMMING CHART on Pages 17-18. 

 
 

HOW TO USE THIS FEATURE:

 

1.  See the “Option Programming” section on Pages 17-18 and change Option #19 from "Monitor Glow Plug Light" to 

one of the delayed time values. (Default setting is to always monitor the PINK Glow Plug input wire.) 

2.  Once this option has changed, the system will wait for the selected time before cranking. 

 
 
 

OPTIONS PROGRAMMING 

 

This EZEE unit has over 20 programmable control options to customize the system for various operating features and 
installer preferences.  Examine the chart on the pages 17-18 along with reading the descriptions that follow on pages 
18-21. You may change one option at a time, or program multiple options in one session.  If you start with the lowest 
option and continue on to higher options, you do not need to repeat steps #1-3 each time.  For example, you can change 
Option #2 to “ON”, then you can continue pressing the program button to get to a higher number option and change it as 
well.  You can only go from low to higher options numbers in one session. 

 
 
 
 
 
 

OPTION PROGRAMMING CHART BEGINS ON NEXT PAGE 

 
 
 
 
 
 
 

16 

 
 
 
 
 
 

Summary of Contents for Ezee Start EZ-777 FM

Page 1: ...r vehicle Crimestopper Security Products Inc and its vendors shall not be liable for any accident resulting from the use of this product This system is designed to be professionally installed into a v...

Page 2: ...e locations for all components to be placed These components include the module itself valet program button possible relays and antenna receiver EZ 90 777TW1 TW2 FM only EZ 91 model does not include i...

Page 3: ...re to terminal 85 connect relay terminals 86 and 87 to 12V constant power Connect terminal 30 to the 12V positive Horn activation wire PIN 10 BLACK MAIN SYSTEM GROUND Connect to chassis metal of the v...

Page 4: ...DULE 12V CONSTANT OR TRANSPONDER Diode isolate if using both PIN 9 YELLOW BLACK FOR ANTI GRIND STARTER DISABLE OUTPUT Relay not included TO IGN 2 MOTOR ACC START CUT BROWN YELLOW BLACK 86 85 MAKE CERT...

Page 5: ...or use as a dome light illumination output Note when using the Brown wire as a Trunk Pop you may also need or want to program option 14 so the system also provides an Unlock signal when the trunk pop...

Page 6: ...Remote Start or Stop when 3 successive Negative pulses are sent to the Green input wire Connect the Green input wire to the Negative lock signal wire of the factory system If your Factory OEM system d...

Page 7: ...ORANGE BLACK OEM DISARM OUTPUT This wire provides a Ground pulse to disarm the vehicles Factory anti theft system prior to a Remote Start Connect this wire to the vehicles anti theft disarm wire This...

Page 8: ...more than just one IGN ACC or STARTER wire in order to start and run successfully If this is the case for your particular vehicle then use the jumper pin located under the access panel on the top of t...

Page 9: ...C 2 TOP WHITE START 2 FUSE PARKING LIGHTS IF NECESSARY 7 PIN High Current Connector IGN SWITCH VEHICLE 10A or 500mA NOTE Heavy duty High Current Ignition circuits greater than 30 AMPS Industrial vehic...

Page 10: ...cle doors Reverse Polarity Many Ford Lincoln Mercury Dodge Chrysler Plymouth and early 90 s GM Trucks Reverse Polarity systems use no relays but instead the door lock unlock motors are controlled dire...

Page 11: ...LUE BLUE 86 85 86 85 87 87 30 87A 30 87A FACTORY FACTORY L L POWER POWER LOCKING LOCKING UL UL RELAYS RELAYS AFTERMARKET MOTOR DOOR LOCK WIRING REVERSE POLARITY DOOR LOCK WIRING GREEN GREEN FUSED FUSE...

Page 12: ...decrease your cranking time respectively The adjustment range is from 80 to 100 in one percent increments Follow steps below to adjust the reference level 1 Open hood or ground Gray wire if no hood p...

Page 13: ...m may flash the lights erratically Erratic light flashing indicates that the system is sensing and tach pulse but it is not programmed into memory To correct this issue follow the tach programming ste...

Page 14: ...TACH PROGRAMMING 1 Open hood or ground Gray hood pin wire if no hood pin is installed 2 Red White wire should be connected to a valid Tach source 3 Start engine with key 4 Press program button 5 time...

Page 15: ...e key start the engine a few times to get a feel of how long the cranking time is Once the Timed Crank mode is turned on the default cranking time is set to a default of 0 50 seconds We recommend begi...

Page 16: ...30 seconds SEE OPTION PROGRAMMING CHART on Pages 17 18 HOW TO USE THIS FEATURE 1 See the Option Programming section on Pages 17 18 and change Option 19 from Monitor Glow Plug Light to one of the delay...

Page 17: ...s Tap the brake once lights flash 1X Tap the brake pedal again Lights flash 2X tap 3 or 4 times for options that have 3 or 4 values 6 When finished turn Ignition OFF close hood or un ground Gray wire...

Page 18: ...17 OEM Disarm Unlock Pulse 0 75 sec Normal or 0 5 Shorter Short Normal 18 Starter Cranking Time Only when option 15 is set for Timed Crank Button 1 0 75 Sec Button 2 0 5 Sec Button 3 1 0 Sec Button 4...

Page 19: ...4 Double Unlock Pulse The unit will send 2 unlock pulses when the 2 Unlock button is pressed This feature may be required for interfacing this alarm with an existing Factory Keyless Entry or Alarm sy...

Page 20: ...Negative IGN output that turns ON and stays on for the duration of the remote start Use this wire to turn on Anti theft bypass adapters for GM or Transponder systems When changed to an Anti Grind this...

Page 21: ...gnal Just select a delay time and do not connect the Pink Glow Plug wire Selections 10 20 30 seconds or Monitor Pink Wire Default 20 Remote Start Run Time This option controls the engine run time for...

Page 22: ...not starting vehicle 3 Press Program Valet button 4 times After a few seconds the unit will flash the parking lights exactly 4 times 4 EZ 90 Press Button 1 Lock of the transmitter to be learned EZ 77...

Page 23: ...system remote CANNOT control an EZ 777TW1 TW2 FM and vice versa See diagram below on how to switch your remote s to vehicle 2 operation To set up the 2 Vehicle operation you must first program your re...

Page 24: ...y Passlock and RF Transponder systems Ford P A T S Many late 1990 s through 2005 vehicles include some type of Anti Theft system which may require a bypass module The vehicle may have more than one Ig...

Page 25: ...INK glow plug input wire See the diagrams below for Jumper Pin configurations JUMPER PLUG SIDE VIEW JUMPER PINS JP1 JUMPERS IGN 2 DEFAULT ACC 2 NEGATIVE PARKING LIGHT 500 mA 12V 10A PARKING LIGHT DEFA...

Page 26: ...ANTENNA DIAGRAM WINDSHIELD ANTENNA LOCATIONS Blue Plug Black Plug EZ 90 EZ 777TW1 EZ 777TW2 EZ 777FM Color of plug and receptacle must match 26...

Page 27: ...XTERNAL RELAYS FOR HIGH CURRENT YELLOW WHITE OEM REARM START ACTIVATION GREEN HORN CHIRP HONK OEM DISARM GREATER THAN 30A IGNITION CIRCUITS ACC GROUND AUX TRUNK POP or DOME LIGHT FUSE FUSE 30A TACH 30...

Page 28: ...ONLINE TECHNICAL SUPPORT www crimestopper com techweb03 html www crimestopper com email crimestopper com Phone 800 998 6880 FAX 805 581 9500 2004 Crimestopper Security Products...